Description
Temp1000S
Integral 1" probe
Temperature Sensor
100Ω Platinum RTD
Temperature Range
Temperature Resolution
Calibrated Accuracy
Memory
Sample Rate
Required Interface Package
Baud Rate
1 year
Typical Battery Life
(15 minute reading rate at 25 °C)
3.6V lithium battery included
Battery Type
*Must be sent to MadgeTech for
battery replacement
Operating Environment
-40 °C to +150 °C, 0 to 100%RH, 60 PSIG
Material
303 Stainless Steel
Body: 4.8" x 1.0" dia.
(122mm x 26mm x dia.)
Dimensions
Probe: 1.0" x 3/16" dia.
(26mm x 5mm dia.)
Weight
8 oz (225 g)
Approvals
** The minimum bending radius of the probe is 2", bending only once.
Avoid bending the probe anywhere along the first 2.5" from the tip.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 150 °C (302 °F).
1.800.561.8187
Temp1000FP
Integral 10.8" flexible
probe** 100Ω Platinum RTD
–40 °C to +150 °C
0.05 °C
+0.5 °C
32,767
2 seconds up to 12 hours
IFC110 or IFC200
2,400
1 year typical
(1 minute reading rate @ 25 °C)
3.6V high-temperature
lithium battery included
*Must be sent to MadgeTech for
battery replacement
Body: 303 Stainless Steel
Probe: 304 Stainless Steel
Body: 5.7" x 1.25" dia.
(145mm x 32mm x dia.)
Probe: 10.8" x 1/8" dia.
(275mm x 4mm dia.)
11.3 oz (320 g)
CE
www.
Product Information Card
Temp1000S
Rugged High Temperature Data Logger with 1" Rigid Probe
Temp1000FP
Rugged Temperature Data Logger with 10.8" Flexible Probe
information@itm.com
.com
Temp1000S and Temp1000FP
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289

Advertisement

loading

Summary of Contents for MadgeTech Temp1000S

  • Page 1 (1 minute reading rate @ 25 °C) 3.6V high-temperature 3.6V lithium battery included lithium battery included Battery Type *Must be sent to MadgeTech for *Must be sent to MadgeTech for battery replacement battery replacement Operating Environment -40 °C to +150 °C, 0 to 100%RH, 60 PSIG...
  • Page 2 Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device cannot be restarted until it has been re-armed by the computer. The Temp1000S and Temp1000FP can withstand up to 150 °C and be used in a dry Downloading data from a data logger environment, or completely submersed.

This manual is also suitable for:

Temp1000fp