7: Operation
7.1: Controls
7.2: Operating modes
Scene Controller
This mode is enabled by default or by setting parameter 20 to 0.
In this mode, the device can activate scenes in the Z-Wave controller
by sending scene ID and attribute of a specific action (using Central
Scene Command Class). Associations do not work in this mode.
Double Button
This mode is enabled by setting parameter 20 to 1.
In this mode the device works as two separate buttons and it uses
associations to control other Z-Wave devices (groups 2-5). You can
control multiple devices of different type in this mode. Every button
can control different group of devices.
operatIon
1
3
2
Button
Action
Clicked once
Clicked twice
Clicked thrice
Held
Released
Clicked once
Clicked twice
Clicked thrice
Held
Released
1. First/
button,
2. Second/
button,
3. LED ring.
Scene ID
Attribute
Key Pressed 1 time
1
Key Pressed 2 times
1
Key Pressed 3 times
1
Key Held Down
1
Key Released
1
Key Pressed 1 time
2
Key Pressed 2 times
2
Key Pressed 3 times
2
Key Held Down
2
Key Released
2