FIBARO   provides   many   advantages   when   compared   to   similar  
systems.   In   general,   radio   systems   create   a   direct   connection  
The   advantage   of   FIBARO   system   is   that   its   devices   apart   from  
achieved  through  other  intermediate  devices.
OPERATING  MANUAL
ROLLER  SHUTTER  CONTROLLER  
confirmation  of  its  reception.  This  operation  confirms  their  status  so  
FGR221  v1.4
to   check   whether   they   are   active.   Safety   of   the   FIBARO   system  
wired  systems.  
Remotely  controlled  Roller  Shutter  Controller  of  FIBARO  system  is  
frequency.  Every  FIBARO  system  has  its  own  unique  identification  
designed  to  control  motors  of  roller  shutters,  awnings,  etc.  
It   has   the   function   of   detecting   the   current   state   of   a   controlled  
device,  e.g.  position  of  roller  shutter.  
Specifications
Power  supply
FIBARO   generates   a   dynamic   network   structure.   After   FIBARO  
system   is   switched   on,   the   location   of   its   individual   components   is  
Power  of  supplied  motor  
signals  received  from  devices  operating  in  a  "mesh"  network.
In  accordance  with  EU  
standards
shutter  connected  to  its  terminals  using  radio  waves,  controllers  and  
Temperature  limits  
Operational  temperature
 
II  Assembling  Roller  Shutter  Controller  
Radio  protocol
Radio  Frequency
Range
1.   Before   installation   ensure   that   the   voltage   supply   is  
Technical  Information
disconnected.
2.  Connect  the  Roller  Shutter  Controller  in  accordance  with  the  
diagram  on  Fig.  1
3.  Place  the  device  in  the  electrical  box.
4.  Arrange   the   antenna   (tips   are   presented   below  diagrams   of  
fig.  1)
DANGER
Danger   of   electrocution!   All   works   on   the   device  
DANGER
Danger   of   electrocution.   Even   when   the   device   is  
Any  
works  
introducing  
changes  
into  
the  
always   performed   with   disconnected   voltage  
Fig.1  Circuit  diagrams  for  the  Roller  Shutter  Controller
TIPS
i
recommended  values.  
NOTES  FOR  THE  DIAGRAM:
Connect   only   in   accordance   with   the   diagram  
presented   i n   t he   m anual.   I mproper   c onnections   m ay  
TIPS  FOR  ARRANGING  THE  ANTENNA:
i
Locate   the   antenna   as   far   from   metal   elements   as  
order  to    prevent  interferences.  
i
Metal   surfaces   in   the   direct   vicinity   of   the   antenna  
may  impair  signal  reception!  
i
operates
Note!  
i
S1   terminal   operates   with   the   shutter   motor   output  
terminal,  operates  with  the  shutter  motor  output  O2.  
down.  
Note!  
i
DICTIONARY:  
                                                                                                                                                                                                                                                             
radio  system
Danger  of  electrocution.
III  Starting  the  operation  of  the  
       Roller  Shutter  Controller
1.  Installing  the  Roller  Shutter  Controller
STEP  1  
Connect  the  device  in  accordance  with  the  circuit  diagram  presented  
[Adding/  Removing]  of    the  Roller  Shutter  Controller  [to/  from]  
L
Z-­wave  network
N
STEP  2  
Home   Center   controller,   as   the   adding   mode   requires   direct  
communication  with  the  controller.
   
STEP  3  
Identify  key  no.  1.  If  the  device  is  connected  in  accordance  with  the  
diagram   shown   in   Figure   1,   this   will   the   key   that   raises   the   roller  
shutter.  
N
STEP  4    
S1 S2 O1
O2
L N
M
Roller  
STEP  5    
B
Shutter
the  device.  
WARNING!  
i
The  Roller  Shutter  Controller  cancels  the  "learning"  
mode   after   key   no.   1   is   pressed   once.   Therefore,  
pressing  key  no.  1  four  times  will  not  add  the  devices  
to  the  network.
WARNING!  
i
switches,   ensure   that   all   switch   contacts   are   open  
to  the  network.  
During   the   installation,   it   is   recommended   to   use   a  
The   Roller   Shutter   Controller   enables   user   to   associate   three  
mono-­stable  keys  or  push-­  button  B.
groups.
Group   I
STEP  6  
The   controller   indicates   that   the   device   is   correctly   added   to   the  
network,  (see  the  manual  of  Home  Center  controller
Group  II
Group  III    for  controllers  such  Home  Center  for  state  reporting
devices,  and  7  MultiChannel  devices  in  group  no.  1  and  no.  2,  group  
the  network  controller.  It  is  recommended  to  use  up  to  10  devices,  as  
2.  Resetting  the  Roller  Shutter  Controller  
The  Roller  Shutter  Controller  provides  two  methods  for  resetting.
Method  I  :  
devices  added  to  associated  groups  may  take  even  a  few  minutes  
Method  II
once  S1  key  and  then  holding  key  S2.
i
3.   Controlling   the   Roller   Shutter   Controller   by  
mono-­stable  or  bi-­stable  switches.
Mono-­stable   switch   (after   releasing   the   push-­button   a   spring  
automatically  pushes  back  and  disconnects  the  button  )
FGR221   Roller   Shutter   Controller   supports   the   operation   of  
assigned  for  the  action.
two  or  more  circuits  inside  one  physical  unit.  
Bi-­stable   switch   (operates   as   a   two-­position   switch,   it   has   no  
spring  that  would  push  back  the  device  after  releasing  manual  
pressure)
V  Configuration
The  Roller  Shutter  Controller  allows  user  to  configure  the  following  
4.   Controlling   the   Roller   Shutter   Controller   using                
i
entering  an  appropriate  value  into  configuration  register  no.  1  
5.   Controlling   the   Roller   Shutter   Controller   using  
OFF.    default  value  0
Fibaro  system  controller  
255
0
1
2
Parameter  no.  10  -­  Turning  off  the  shutter  positioning  function
default  value  0
Options  for  changing  parameter  0,  1
0
1
Parameter   no.   14   -­   Switch   type   connector,   you   may   choose  
between  mono-­stable  and  bi-­stable  switches  default  value  0
Options  for  changing  parameter  0,  1,  2
Parameter  no.  20  -­  Saving  the  position    "Favourites"                      
IV  Association
or  scene  
Possibility   to   change   the   configuration   of   the   following  
parameters  [30  -­  33].
0
WARNING!  
frames
i
Association   ensures   direct   transfer   of   control  
1
after  detecting  an  alarm
without  participation  of  the  main  controller.
2
after  detecting  an  alarm
       
Parameter  no.  30  -­  General  Alarm,  set  for  shutter  no.  1
Parameter  no.  31  -­   A larm  of  flooding  with  water,  set  for  relay  the  
shutter.
Parameter   no.   32   -­   Smoke,   CO,   CO2   Alarm.   Set   for   the   roller  
shutter.
Parameter  no.  33  -­  Temperature  Alarm,  set  for  roller  shutter
VI  Additional  Functionality
WARNING!  
commands  and  a  new  command  is  issued,  then  the  
Operating  alarm  data  frames
current  one  command  transmission  is  interrupted  to  
send  new  commands.
The   device   may   respond   in   the   following   manner   to   received  
WARNING!  
Entering   incorrect   parameters   may   cause   incorrect  
operation  of  the  Roller  Shutter  Controller.
frames
after  detecting  an  alarm
shutter  after  detecting  an  alarm
Position  indicating
detect   the   current   position   of   roller   shutters,   awnings   and   similar  
devices.    For  proper  operation  of  the  mechanism,  it  is  necessary  to  
use  a  motor  with  mechanical  limit  switches.  Correct  operation  of  the  
position   detecting   mechanism,   when   using   motor   with   overload  
VII  Operating  the  Shutter  Roller  Controller
The   Roller   Shutter   Controller   may   be   operated   using   the  
following  control  elements:
VIII  Procedures  for  malfunctions
The  device  does  not  respond  to  a  pre-­programmed  transmitter:
the  programming  process.

Advertisement

loading
Need help?

Need help?

Do you have a question about the FGR221 and is the answer not in the manual?

Questions and answers

Summary of Contents for FIBARO FGR221

  • Page 1 Group  III    for  controllers  such  Home  Center  for  state  reporting The   advantage   of   FIBARO   system   is   that   its   devices   apart   from   Metal   surfaces   in   the   direct   vicinity   of   the   antenna  ...
  • Page 2   time   and   money   spent   to   initiating   guarantee   procedure.   If   remote  support  is  insufficient,  the  Customer  shall  fill  the  guarantee   FIBARO In  case  of  any  technical  questions  contact  customer  service  centre  ...