FAILURE
Unable to
obtain desired
temperature
Chemical
dispenser not
flushing
27
Part. 14000101 Rev. 12/2019
06 MAINTENANCE
CAUSE
· Temperature sensor malfunction
· The hot water inlet valve malfunction
· Program set incorrectly
· No water or the water pressure is too
low
· 4-way water inlet valve malfunction
· Program set incorrectly
SOLUTION
· Check the temperature sensor, replace if necessary
· Check hot water inlet valve
· Change program
· Check external water supply
· Check program settings, modify if necessary
· Check the 4-way inlet valve, replace if necessary
· Check program
®/™ ©2019 Unity Laundry Systems. All rights reserved.