NOTE: Dependent on the model and configuration, the controllers have
been programmed to only allow a lower compartment temperature
adjustment range as specified within the chart below. The upper
compartment range is not limited, but should always be kept within
the specified range shown in the table for the upper compartment. See
the chart below for the specified range allowed for your unit.
Signature Series – Dual-Zone Units
Model
HP24Z
Upper 33° - 42°F / Lower -10° - 10°F
HP24C
HP24D
Temperature Scale
To change F to C, press and hold the down arrow for 3 seconds.
To Start A Manual Defrost (HP24Z Models Only)
Press and hold the DEFROST button (melting snowflake) for 3-5
seconds. Melting snowflake will illuminate.
15", 24" Single Zone, 24" Shallow Depth, and ADA Controls
To Set Target Temperature
Press and release the SET button. Display will show the current
temperature setpoint.
To Change Setpoint Temperature
1. Press and hold the SET button until the display shows the
current setpoint temperature with the "F" flashing.
2. Use the UP and DOWN arrow button to scroll to the desired
temperature.
To Start A Manual Defrost (Freezer Models Only)
Press the DEFROST button (melting snowflake).
To See Maximum Stored Temperature
Press the UP arrow button to see the maximum stored tempera-
ture. To reset the maximum stored temperature, while displayed,
press and hold the SET button until 'rst' flashes in the display.
To See Minimum Stored Temperature
Press the DOWN arrow button to see the minimum stored tem-
perature. To reset the minimum stored temperature, while dis-
played, press and hold the SET button until 'rst' flashes in the
display.
On/Off
Press the ON/OFF button to turn the unit on or off.
NOTE: Dependent on the model and configuration, the controllers
have been programmed to only allow a temperature adjustment
within a specified range. See the chart to right for the specified range
allowed for your unit.
Range (F)
Upper 45° - 65°F / Lower 33° - 42°F
Upper 51° - 65°F / Lower 45° - 55°F
PERLICK RESIDENTIAL UNDERCOUNTER USE & CARE GUIDE
Signature Series – HP15 Models
Model
HP15R
HP15B
HP15W
HP15T
Signature Series – HP24 Models
Model
HP24R
HP24F
HP24B
HP24W
HP24T
Signature Series Shallow Depth
Model
HH24RS
HH24BS
HH24WS
C-Series Models
Model
HC24RB
HC24BB
HC24WB
ADA-Compliant Series
Model
HA24FB
HA24RB
HA24BB
HA24WB

LED Functions

The following table describes LED functions.
LED
Mode
Flashing
Flashing
Audible alarm will sound if the door is left ajar for longer than one
minute. Fully closing the door will clear the alarm condition, pro-
longed time spent with the door open can damage the equipment.
perlick customer service (800)558-5592 | 5
Min Temp Set
Max Temp Set
33° F
33° F
45° F
33° F
Min Temp Set
Max Temp Set
33° F
-10° F
33° F
45° F
33° F
Min Temp Set
Max Temp Set
33°
33°
45°
Min Temp Set
Max Temp Set
33°
33°
45°
Min Temp Set
Max Temp Set
-10°
33°
33°
45°
Function
ON
Compressor is on
Anti-short cycle
delay is on
ON
Defrost is on
ON
Alarm is on
You are in the process of
programming the unit
42° F
48° F
65° F
42° F
42° F
10° F
48° F
65° F
42° F
42°
48°
65°
42°
48°
65°
10
42°
48°
65°