(7)
1
cess, then the synergic function ensures that all other synergic parameters are adjusted
automatically.
2
menu 2nd level.
The value continuously rises during welding in line with the permanently increasing
energy input.
The final value is stored after the end of welding until welding starts again or the power
source is switched back on - the HOLD indicator lights up.
34
"Parameter selection" button (right)
For selecting the parameters listed below
The relevant symbol lights up when a welding parameter is selected.
Arc length correction
For correcting the arc length
Welding voltage in V (synergic parameter)
Before welding begins, the device automatically displays a standard value based
on the programmed parameters. The actual value is displayed during welding.
Arc-force dynamic
For influencing the short-circuiting dynamic at the moment of droplet transfer
- ... Harder and more stable arc
0 ... Neutral arc
+ ... Soft and low-spatter arc
Real Energy Input
For displaying the energy applied during the welding operation
If one of these parameters is selected in the MIG/MAG standard synergic welding pro-
This parameter can only be selected if the EnE parameter is set to ON in the Setup
2
1
(7)