    Index Product Information Introduction Product Features Unpacking Product Layout Installation Positioning the pump Installing the App Register your cloud account Connect your dosing pump to the cloud Programming the dosing pump Setting the dosing plans Advanced plan adjustments Manual Addition Calibration Advanced Settings Renaming the Dosing pump...
  • Page 3: Product Information

    Product Information Introduction The D-D P4 Cloud is a 4-channel intelligent dosing pump with WIFI control. This unit will allow the automated addition of liquid additives and elements in an accurate, controlled manor to your aquarium. In a reef aquarium regular dosing of elements such as Calcium, Magnesium, KH buffers and trace elements set to the needs of the aquarium will help produce a stable environment.
  • Page 4: Product Layout

    Product Layout 1.Pump head (Counter clockwise rotation) 2.Outlet 3. Inlet 4. WIFI status indicator (Red) 5. Power indicator (Green) 6. Reset button (Reset) 7. CAN communication interface (for future development) 8. Power input (DC 12V) Indicator Status Description Connected to the Cloud via router Disconnected from the router Status indicator Fast Flashing...
  • Page 5: Installation

    Installation Positioning the pump The dosing pump is a self-priming pump. When there is big difference between the inlet and the outlet height, siphoning may occur. In order to avoid siphoning, the dosing pump should be placed in a position to ensure that the height difference between the inlet and the outlet is within 0.5m. The inlet tube should be as short as possible, and the outlet tube should not be submerged.
  • Page 6: Register Your Cloud Account

    Register your Cloud Account You will need to register an account and login on the Kamoer remote app before using your dosing pump. Choose to register via E-mail or mobile then follow the onscreen instructions to complete registration and login. Version 1.0...
  • Page 7: Connect Your Dosing Pump To The Cloud

    Connect the Dosing pump to the Cloud Make sure your mobile device is connected to your home network, the location services on the mobile device are enabled and that the Kamoer Remote app permissions are set correctly from your mobile devices settings page. Please note the device does not support 5G Wi-Fi and cannot use a 5G Wi-Fi hotspot.
  • Page 8: Programming The Dosing Pump

    Press and hold the reset button on the right panel side of the dosing pump. When the red status indicator flashes twice, and the buzzer sounds twice, release the button immediately. Wait another 3 seconds. The red status indicator will then start to flash rapidly. The device enters configuration mode.
  • Page 9: Setting The Dosing Plans

    Setting the Dosing Plans To set the dosing plan select the pump head you want to programme by tapping on it. This will open the plan page for that pump head. Tap on ‘Cycle time’ and choose if you want to set up the schedule dosing frequency ‘By Days’ or ‘Weekly’...
  • Page 10 For example, if the first two channels are set to dose 10ml, between 12:00 and 23:00, over 8 doses with the chemical interference set to ‘0’. Both enter the first dose at 12:00 at the same time. They will then continue to dose at exactly the same time throughout the day until they complete their program.
  • Page 11 In the example below Pump 1 has been set to dose every three days a total of 10ml, over 24 smaller doses, between 00:00 and 23:59. The dosing container has 999.6ml of solution left in it and should therefore last approximately 99 days. Version 1.0...
  • Page 12: Advanced Plan Adjustments

    Advanced Plan adjustments When a plan has been created advanced manual adjustments can be made. Open the app, choose the device then select the pump in the plan page. Tap on the blue arrow icon at the bottom right corner of the plan group and a detailed breakdown will appear. This shows the individual plan points and associated dosing volumes.
  • Page 13 The plan group name and time can be altered by tapping on the plan group and then entering the new name or time as required. Select ‘Save’ to confirm the changes. The individual plan points will not be changed by doing this. If the plan points fall outside the new time set for the plan group they will have to be manually changed as described in this manual.
  • Page 14 Plan groups and plan points can easily be deleted by swiping them to the left. When a plan point is deleted it will remove the volume of that dose from the overall group. The adjusted volume will be shown at the top of the pump page. To reset all the plan points in a group, select the ‘Quick add’...
  • Page 15: Manual Addition

    groups will be dosed at the same time. For example, if a dose of 1ml in plan A and a dose of 2ml in plan B are set for the same time the pump will dose 3ml in total. Manual addition The pump can be used to add a manual dose if required.
  • Page 16: Calibration

    If you want to stop the manual dose tap the ‘Start’ button (that will now be displaying ‘Stop’) again to cancel the operation. There is a lag when pressing the stop button so this should not be used as a method to stop the pump at an exact point.
  • Page 17 Set the time for pump calibration by selecting ‘Add time’ and scrolling through to the desired time. This can be set up to 60 seconds. For increased accuracy, a longer calibration time is best. Please be aware the measuring cylinder needs to be large enough to hold the volume of the water for the calibration.
  • Page 18: Renaming The Dosing Pump

    Advanced Settings At the bottom right hand corner of the ‘Plan’ page there is a settings option. In this you can: Rename the Dosing Pump and the individual dosing pump heads. In settings tap on ‘Name’ and the settings page will open. Select the pump name or the channel name you would like to change, enter the new name and tap ‘Save’...
  • Page 19: Time Setting

    Time setting The unit should automatically sync to the correct time when setup and keep the correct time during a power outage. If the time is incorrect and needs to be adjusted tap on ‘Time Setting’ and select ‘Time Sync’. It is normal for the ‘Firmware time’ to lag behind the ‘App Time’ by 1-5 seconds due to the time taken to process data between the app and the device.
  • Page 20 WARRANTY: Should any defect in material or workmanship be found within 12 months of the date of purchase D-D The Aquarium Solution Ltd undertakes to repair, or at our decision, replace the defective part free of charge. Our policy is one of continual technical improvement and we reserve the right to modify and adjust the specification of our products without prior notification.