11 Maintenance

11.3 Maintenance Program Summary

P14 to P33
Free programming locations
P34
Deodorizing:
The following maintenance programs are installed in the P12/P15
P9
Slimsorba maintenance (only
for machines with Slimsorba)
P10/P
Filter maintenance 1/2
35
P36
Distillation maintenance
P37
Fill tanks
P38
From tank 1 to cage
P39
From tank 2 to cage
P40
From tank 1 to distillation
P41
From tank 2 to distillation
P42
From cage to distillation
P43
Prepare stock solution
P44
Transfer pumping of
distillation residues
P45
Program not assigned
P46
Rinse sight-glass, tank 2
P47
From tank 3 to cage
P48
From tank 3 to distillation
P49
Program not assigned
P50
Neutralization distillation
57
Attention: Always select this program if the loading door
will not open.
For desorption of the Slimsorba at times other than during
cleaning cycles. The program has two phases: desorption
and carbon cool-down.
Start of automatic filter maintenance program with
spinning and simultaneous 50% draining to the still. Then
additional spinning and complete emptying into the still.
Finally, filter circuit and, if filter powder is used, precoating
with the filter powder. Pumping to work tank and spin to
still with subsequent drying and reduction.
If filter powder is used, fill the bag that comes with the
machine and put it in the cage before the start.
Still stripping and subsequent reduction or program
sequence "emission-free still rake out"
Fill the clean tank, then overflow into the work tank
For cleaning the work tank
For cleaning the clean tank
Addition of drycleaning detergent in the work tank solvent
by preparation in the pump circuit, with dosing via the
dosing unit (manual operation); then drying with reduction
(Only with emission-free still rake out system)
For interior cleaning of the sight-glass on tank 2
Pump from tank 2 to tank 2
For cleaning the extra tank
- Remove button trap strainer
- Fill in product
- Replace button trap strainer
- Pump from work tank and wash neutralization agent into
the still.
- Subsequent drying with reduction.
11
11.3
P12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P 15