Maintenance; Operation And Maintenance Summary - BÖWE P 12 Instruction Manual

Dry cleaner
Hide thumbs Also See for P 12:
Table of Contents

Advertisement

11 Maintenance

Attention: Warranty claims will only be accepted if maintenance has

11.1 Operation and Maintenance Summary

When starting operation:
Turn on steam supply
Turn on room ventilation system
Turn on cooling water supply
Turn on compressed air supply
Open condensate valve
Turn on machine main switch
Start deodorizing program P34, press
"STOP" button when program ends and
signal sounds
When stopping operation:
Start maintenance program P10 when
economy filter at 1.5 bar pressure (at
least every 50 cycles)
Start distillation maintenance P36 and
wait for signal
Turn off machine main switch
Turn off steam supply
Close condensate valve
Turn off cooling water supply
Turn off compressed air supply
compressor
Turn off room ventilation system or
switch to night operation
Inspection and maintenance work:
Daily: (before starting the first cycle)
Check machine for leaks
Check solvent safety trough for solvent
If needed, add neutralization agent to
still
Clean button trap strainer and lint filter
see
11.5.1)
Drain water separator water trap into the
process water tank (or safety separator)
Check process water tank (or
separator), drain if necessary. Dispose
of according to regulations for your
country!
Check the liquid level in the cleaning
agent container
Check small steam generator pressure
gauge level (elec.)
Machine is ready for operation
52
been performed properly! Follow safety regulations!
Weekly:
Monthly:
Semi-annually:
Annually:
safety
Attention:
Empty and clean water separator
Start Slimsorba maintenance P9
Start drum back plate flushing P51
Wash lint filter mat
Drain water from compressed air
armature
Clean the sprayer dirt strainers and
spray nozzles
Check the function of the disposal vessel
overfill sensor
Check pH level (7 –9 indicates good
solvent condition)
Check solvent levels in the tanks
Clean water and steam feeder strainers
Lubricate cage bearing
Lubricate fan shaft gasket
Clean air cooler
Clean tanks
Check V-belt tension, retension
Retighten screwed unions
Machine inspection (following VBG 66)
Check sacrificial anode, replace if
necessary
Remove filter disc and clean in
machine (program P6)
Check Slimsorba activated carbon
Check water level in still heating
chamber (elec.)
Close loading door and
maintenance openings again
immediately
Use only lithium-based lubricating
greases, such as:
- ALVANIA 3 (SHELL) - MARSON L2 (FINA)
- BEACON 2 (ESSO)
11
11.1
- LGMT 3 (SKF)
P12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P 15

Table of Contents