6 Operation
6.1.5

Filling the Water Separator

Use program P40 to pump solvent from tank I to the still for about 15 seconds.
Start the distillation with P36. The water separator fills automatically during distillation.
6.1.6

Filling the Economy Filter

- Enter the filter maintenance program P10 (P35 for 2nd filter).
- Press the "hold" button.
- Press the " ⇑ " button repeatedly until step n10 is displayed.
- Start the program.
When using filter powder (optionally):
- First fill the precoating bag with the prescribed amount of filter powder (1.2 kg/2.6 lb) and place it into
the cage, then start P10 (or P35) as described above.
Attention:
Do not use filter powder on machines with an emission-free still
rakeout system.
6.1.7

Electric Steam Generator for the Slimsorba (Optional Equipment)

In the electrically heated version, the Slimsorba is also equipped with an integrated steam generator C.
To prepare the steam generator C for operation, perform the following jobs in the order given:
1.
Remove screw-in plugs (1), (3) and (7).
2.
Open aeration valve (2)
3.
Fill water in filler stub (1) until the water comes out at overflow (3).
4.
Replace screw-in plugs (1) and (3) so that they seal tightly.
(Do not use hemp, use only PTFE tape)
5.
Close aeration valve (2)
6.
Start P9
7.
Wait until the pressure gauge (4) display shows that the steam pressure is 5 bar.
8.
Open aeration valve (2) until steam comes out and then close the valve again.
(Caution: danger of scalding)
9.
Screw in the screw-in plugs (7) again.
10.
If the error message "E0050" appears on the display, there is a lack of water in the steam
generator, which is triggered by the overheating protection (6). Let the steam generator cool
down until the pressure gauge (4) shows 0 bar.
Then refill with water, as described in steps 1 to 9.
11.
Stop program P9 after the venting and go to the next step n2 (reduction,
cooling the carbon).
Start again and let the program run until the end.