Central heating

Possible settings for room heating.
Central heating
↳ Setting
↳ Minimum flow temperature
↳ Maximum flow temperature
↳ Outdoor temperature compensation
↳ Offset curve
↳ Delay
↳ Circulation pump
16
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Heating / Off / Requirement
Heating
Off: Room heating is off.
Heating: Constant heating in relation to min./max.
Requirement: The flow temperature is regulated
automatically by the curve setting
5 - 40 ºC
25 ºC
Here, the minimum flow temperature is set. The
setting overrides a potentially lower temperature
from the curve control. This function may be relevant
with, for example, underfloor heating if you should
want a minimum comfort temperature.
25 - 70 ºC
50 ºC
Here, the maximum flow temperature is set. The
setting overrides a potentially higher temperature
from the curve control.
1 - 10
4
Choose which curve the control system should
regulate in accordance with
-15 - 10 ºC
0 ºC
You can shift the curve to best fit the heating
requirements of the dwelling
0 - 30 minutes
10 minutes
Set a chosen delay for when the central heating should
start operating, once a heating requirement has been
registered.
Continuous / Energy
Continuous: The pump is running constantly
Energy: The pump runs when required