Adaptec SCSI RAID 2010S/2015S Installation Guide
SCSI termination is configured through the SMOR utility or from
the Configure Host Bus Adapter window in Adaptec Storage
Management. The controller has only these termination settings:
Setting
Function
On
Default—Enables the controller termination built.
Off
Disables the built-in controller termination. Use only if
the controller will not be situated at one end of the cable.
The following figure shows various SCSI cabling examples for a
single bus. Terminate your SCSI devices as shown in the examples,
ensuring that the devices at the ends of the cables are terminated,
and the devices in the middle are not terminated. If only one cable
is attached, then one end is the controller, and must have its
termination enabled, as indicated in the figure where the circled T
is in the controller.
Note: Each channel being used on a multichannel ZCR adapter must
be terminated properly for its configuration. The figure shows use
with a motherboard channel having both an internal and
external connection. Your motherboard may differ.
External
Wide SCSI
T
2-4
T
Internal Wide SCSI
External
Wide SCSI
T
T
=Terminated
T
Internal Wide SCSI
T
T
T