The internal wiring diagram of the Lynx Shunt VE.Can
3.2. Main fuse
The Lynx Shunt houses the main system fuse.
The fuse is being monitored by the Lynx Shunt VE.Can and, if the fuse blows, the power LED turns red and an alarm message is
sent to the GX device.
The relay can be driven by the blown fuse parameter.

3.3. Battery Monitor (shunt)

The Lynx Shunt VE.Can battery monitor operates in a similar fashion as the other
Victron Energy battery
monitors. It contains a
shunt and battery monitor electronics.
Readout of the battery monitor data is via a GX device or the VRM portal.

3.4. Alarm relay Lynx Shunt VE.Can

The Lynx Shunt VE.Can has an alarm relay. This relay can be programmed via the GX device to open or close using the following
parameters:
• Battery State of charge
• Battery voltage
• Battery temperature
• Fuse blown
The alarm relay can, for example, be used to start or stop a generator based on battery state of charge or battery voltage. The
alarm messages that are send to the GX device or to the VRM portal are programable in a similar fashion.