About CMD3—Sample and Trigger Setup
Filter (Continued)
Note: If
parameter in Sample and Trigger Setup (
display of collected data), the default (no filtering) is used.
Examples: Sample and Trigger Setup Instruction
{3,.25,100}
{3,.0002,99,
2,1,2.9}
46
CBLé System Guidebook
or Statistics is requested, or when the Number of Samples
CH31
3=
.25=
100=
3=
.0002=
99=
2=
1=
2.9=
CMD3
Sample and Trigger Setup command.
Take a sample every 0.25 seconds.
Collect 100 samples.
Default values used for trigger and remaining
parameters.
Sample and Trigger Setup command.
Take a sample every 200 msec.
Collect 99 samples.
Software triggering on rising edge.
Trigger on
CH1
.
Trigger when voltage exceeds 2.9 Volts.
(Continued)