ClareOne Ceiling Mount 360 PIR Installation Sheet
Last modified: 10/22/20
Part Number: CLR-C1-360PIR
Description
The ClareOne Ceiling Mount 360 PIR sensor is a passive
infrared motion detector designed for ceiling mount.
The compact design allows for easy installation while the
sensitivity settings provide adaptability for different
environments.
The motion detector is designed for a ceiling mount application
that provides a 360° detection range.
Notes
•
Do not mount the sensor outdoors.
•
Avoid areas with pets.
•
Do not mount the sensor near ceiling fans or heating
ducts.
•
Avoid placing the sensor in sight of windows and direct
sunlight.
Installation
Before installing the sensor, carefully select the desired
location and sensitivity settings.
Location
The sensor's coverage pattern is dependent on mounting
height. Areas can be masked off to prevent unwanted
detection.
Mounting height
Detection area
8 ft (2.4 m)
20 ft (6.09 m)
10 ft (3.04 m)
30 ft (9.14 m)
12 ft (3.65 m)
45 ft (13.71 m)
Detector sensitivity can be set to allow for harsher
environments with varying temperatures.
© 22OCT20 Clare Controls, LLC.
Figure 1: Detection area
Sensitivity setting
The sensor has 2 sensitivity settings: low and high.
Low (Lo): The recommended setting, allows for some
environmental movement.
High (Hi): A quick response, used for quiet areas that do not
expect environmental noise.
To select the sensitivity level:
1.
Gently twist the sensor top and pull the domed top away
from the base.
2.
Place the jumper into the desired sensitivity level (Lo or
Hi).
Lo Sensitivity: Jumper placement in the top two pins.
Hi Sensitivity: Jumper placement in the bottom two pins.
3.
Replace the sensor top, twisting it firmly into place.
LED
The LED jumper is used to enable/disable a red LED to
illuminate when movement is detected. The red LED does not
illuminate unless the LED jumper is installed across the pins.
Note: Leaving the LED jumper installed greatly reduces the
sensor's battery life.
1 / 4
DOC ID – 1996 • Rev 01
Need help?
Do you have a question about the ClareOne and is the answer not in the manual?
Questions and answers