Weltem AmeriCool WMC-2500 Owner's Manual

Weltem AmeriCool WMC-2500 Owner's Manual

Modular multi air conditioner

Advertisement

Quick Links

WPC-15000
Owner's Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, oper-
ate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and property damage! Retain instructions for future reference.
Modular Multi Air Conditioner
Descrip on
Weltem Modular Mul Air condi oner feature mul -func on spot cooler providing various acces-
sories available to fi t customer needs. This Unit is used to spot cooling for large areas where cool-
ing of the en re area is not prac cal or possible. A dedicated spot cooling thermostat controls the
unit in this applica on. This Unit can also be used in smaller areas for room cooling.
A control panel provides ease of use and contains a self-diagnos c func on and display, showing
opera ng modes, room and set temperatures, and faults, If an abnormal opera on occurs, a visual
display of the fault is shown.
Suitable applica ons include :
a factory or work place, computer rooms, emergency cooling, outdoor event, etc..
Unpacking
A er unpacking the unit, carefully inspect unit for any damage that may have occurred during
transit. Check for any loose, missing or damaged parts.
by
1
Owner's Manual
WMC-2500
WMC
WMC-2500
Fig
Figure 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AmeriCool WMC-2500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Weltem AmeriCool WMC-2500

  • Page 1 Figure 1 Descrip on Weltem Modular Mul Air condi oner feature mul -func on spot cooler providing various acces- sories available to fi t customer needs. This Unit is used to spot cooling for large areas where cool- ing of the en re area is not prac cal or possible. A dedicated spot cooling thermostat controls the unit in this applica on.
  • Page 2: Table Of Contents

    WMC-2500 Owner’s Manual Table of Contents SPECIFICATION....................4 GENERAL SAFETY INFORMATION..............4 APPLICATIONS....................6 Portable Server Rack Mounted, Hang Stack ASSEMBLY (STANDARD)..................7 Component Parts Power Cord Holder ASSEMBLY (PORTABLE)...................8 Component Parts Handle Cool air duct assembly Caster ASSEMBLY (SERVER RACK)................9 Component Parts Universal adjust Rack Assembly Rack Diff...
  • Page 3 WMC-2500 Owner’s Manual Thank you for selec ng this AmeriCool by Weltem Modular Air Condi oner. It provides you with spot cooling for large areas where cooling of an en re area is not prac cal or possible. Please read this manual before installing the WMC-2500 as it provides impor-...
  • Page 4: Specification

    WMC-2500 Owner’s Manual Specifi ca ons Cooling Capac- Power Consump- Rated Cur- EER Btu/ Model No. Power Supply Ph-V-Hz ity Btu/h on Wa s rent Amps WMC-2500 Single Phase, 115V, 60Hz 10,000 1000 10.0 Power Cord Power Cord Length Dimensions Model No.
  • Page 5 WMC-2500 Owner’s Manual 7. DO NOT cover or obstruct the unit’s inlet and outlet grilles. 8. DO NOT use the unit in areas where it will be exposed to rain or water. 9. NEVER unplug the while it is opera ng. DO NOT use the unit in wet environments, such as a laundry room, to avoid the risk of electrical shock.
  • Page 6: Applications

    WMC-2500 Owner’s Manual Applica ons With various accessories, Modular mul air condi oner provides best applica on to suit cus- tomer’s individual needs. PORTABLE - This unit has ability to move easily from room to room using portable kit. It is available spot cooling for large areas where cooling of the en re area in not prac cal.
  • Page 7: Assembly (Standard)

    WMC-2500 Owner’s Manual ASSEMBLY (Standard) COMPONENT PARTS Display /Control Panel Cool Air Outlet Evaporator / Filter Figure 2 - front and Right Side View Exhaust Air Outlet Electrical Access Drain Pump Hose Panel Connector Condenser / Filter Power cord Figure 3 - rear and Power cord Holder Le Side View POWER CORD HOLDER...
  • Page 8: Assembly (Portable)

    WMC-2500 Owner’s Manual ASSEMBLY (Portable) COMPONENT PARTS Handle Cool air duct Caster Figure 5 - portable kit a achment Figure 6 - handle Figure 7 - cool air duct a achment assy a achment HANDLE COOL AIR DUCT ASSEMBLY 1. Take out the handle 2 pcs from the acces- 1.
  • Page 9: Assembly (Server Rack)

    WMC-2500 Owner’s Manual ASSEMBLY (Server Rack) COMPONENT PARTS Rack diff user Universal adjust * See Figure 19 on page 12. Rack assembly Figure 9 - server rack kit a achment Figure 10 - installa on in 19” server rack RACK ASSEMBLY 1.
  • Page 10: Assembly (Mounted, Hang)

    WMC-2500 Owner’s Manual ASSEMBLY (Mounted, Hang) COMPONENT PARTS Condenser intake air outlet Eva intake air outlet Figure 14 - Rear and Figure 13 - Front and Le Side View Right Side View CONDENSER INTAKE AIR DUCT FLANGE 1. Remove condenser intake air duct fl ange (in- cluded fi...
  • Page 11 WMC-2500 Owner’s Manual HANGING ASSEMBLY 1. Install 1/2” threaded rod and vibra on insulator to ceiling. 2. Remove Hanging assembly 1 set (2ea) from carton. 3. Place the hanging assy horizontally on the base of air condi oner. 4. Use screw (enclosed inside of box with hanging kit) to install as shown in Figure 17.
  • Page 12: Assembly (Stack)

    WMC-2500 Owner’s Manual ASSEMBLY (Stack) COMPONENT PARTS Figure 19 - universal adjust a achment UNIVERSAL ADJUST 1. Take out the universal adjust 4 pcs from the acces- sory box. 2. Place the universal adjust on the base panel of unit. 3.
  • Page 13: Installation Guide

    WMC-2500 Owner’s Manual Installa on Guide WARNING REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in areas where fl ammable gas leakage may occur. Do not use the unit in a corrosive atmosphere. Do not use the unit above 18˚C(64.4˚F)~45˚C(113˚F) Do not install the unit on uneven or sloping surface.
  • Page 14: Operation

    WMC-2500 Owner’s Manual Opera on CONTROL PANEL DEHUMID. Figure 21 - Display/Control Panel 1. POWER BUTTON Ac vates unit when POWER BUTTON is pressed. (Fan stats on low speed.) If power bu on is pressed during opera on, unit stops. 2.
  • Page 15 WMC-2500 Owner’s Manual 6. TARGET TEMP Displays the unit set temperature for ROOM/COOL mode only. 7. SET TEMP BUTTONS Change target temperature/data value by +/-1. Change data value by +/- 10 by pressing con nu- ally. Press the SET TEMP BUTTONS to set temperature. Upper bu on is to higher temperature and Low bu on is to lower temperature.
  • Page 16: Maintenance

    WMC-2500 Owner’s Manual Maintenance FILTER CLEANING (Without fl ange) There are 2 fi lters in the unit. The evaporator fi lter is located at the front of the unit. The con- denser fi lter is located at the rear of the unit. 1.
  • Page 17 WMC-2500 Owner’s Manual FILTER CLEANING (With fl ange) 1. Loosen up 2 bolts on fl ange. 2. Slide fi lter up and use vacuum cleaner to remove the dust from the fi lter. 3. If the fi lter is heavily covered with dust and dirt, warm water and mild soap or neutral deter- gent may be used to wash the fi...
  • Page 18 WMC-2500 Owner’s Manual Product Portable Air Condi oner Customer: Please read and keep this Model No. manual for future reference and keep Date of Purchase sales receipt as proof of purchase. Place of Purchase Serial No. Period of Warranty SELF-DIAGNOSTIC CODES (See Table 1) The alarm light is ac vated if abnormal opera on occurs, and a code is displayed on the control panel.
  • Page 19 WMC-2500 Owner’s Manual SELF-DIAGNOSTIC ALARM CODES Alarm Display Problem Cause Correc ve Ac on • Do not use the air Frost preven on • Indoor heat exchanger condi oner if ambient sensor and temperature too low temperature is lower Abnormal •...
  • Page 20: Wiring Diagram

    WMC-2500 Owner’s Manual Wiring Diagram POWER 1P AC 115 1P AC 208 / 230V (1S1) (1S2) (IC) OUT_HUMIDITY OUT_HUMIDITY (dE) SENSOR SENSOR DRAIN PUMP (Fd) (PS) DEHUMID. (FT) (option) DATA CABLE Figure 26 - Circuit Wiring Diagram...
  • Page 21: Troubleshooting

    WMC-2500 Owner’s Manual Troubleshoo ng chart Symptom Possible Cause(s) Correc ve Ac on 1. Check the power supply 1. Reset the circuit breaker and to verify that power is restart the unit available to the unit The unit doesn’t work 2.
  • Page 22 Where and when the unit was purchased. d. All of the model informa on about your AmeriCool by Weltem Modular Air Condi oner. e. Any informa on on the failure, including LED’s that may or may not be illuminated.
  • Page 23: Limited Warranty

    TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY, AS LIMITED HEREIN, SHALL BE IN LIEU OF AND EXCLUSIVE OF ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, ON THE PART OF AMERICOOL INC., OR WELTEM CO.,LTD. WHETHER ARISING FROM LAW, COURSE OF DEALING, US- AGE OF TRADE, OR OTHERWISE, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANT-ABILITY OR FITNESS OF A PARTICULAR PURP OSE OR ANY LIABILITY FOR COMMERCIAL LOSSES BASED UPON NEGLIGENCE OR MANUFACTURER’S STRICT LIABILITY.

Table of Contents