Customer Account Code; 10.20 Downloading Access Code; 10.21 Zone Alarm Reporting Codes - Pyronix ATLAS 4 Installation Instructions Manual

Led remote keypad
Hide thumbs Also See for ATLAS 4:
Table of Contents

Advertisement

10.18
Central Monitoring Station Second Telephone Number
Enter
By pressing the
Press
to store entry.
A number consisting of 16 digits will be stored automatically when the last digit is entered.
10.19
Customer Account Code (Issued by Central Monitoring Station)
Enter

10.20 Downloading Access Code

Enter
followed by the 4 digit code.

10.21 Zone Alarm reporting Codes

Enter
followed by 2 digits for each alarm zone. To disable an event insert blanks in place of the two
digits.
Example: to program alarm zone reporting codes 68 and 69 to zones 2 and 4 respectively the following would be
entered:
To use HEX codes, use the
Reporting codes are automatically stored after pressing the
10.22
Zone Tamper reporting Codes
Enter
To use HEX codes, use the
Reporting codes are automatically stored after pressing the
Page 18
followed by the telephone number. (Up to 16 digits)
a "
" displayed to cause a 2 second pause during dial out.
followed by the 4 digit code. e.g. 4 digit 1,2,3,4.
Alarm zone 1
Alarm zone 2
Alarm zone 3
Alarm zone 4
key to select the character required and the
Enter 2 digits for each tamper zone. To disable an event insert blanks for both digits.
Tamper zone 1
Tamper zone 2
Tamper zone 3
Tamper zone 4
Panel Tamper
key to select the character required and the
e.g. 2 digit code
key.
e.g. 2 digit code
Refer to 10.11 Panel Tamper
key.
key to accept.
key to accept.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATLAS 4 and is the answer not in the manual?

Questions and answers

Table of Contents