Commissioning
6.3
Commissioning procedure
6.3.1
Planning the system in partner application
6.3.2
Registering the setup medium in partner application
44
Commissioning
The device is put into operation in 5 work steps:
1
Planning the system in partner application
2
Adding setup medium in partner application
3
Connecting the device to the power supply
4
Configuring the Ethernet interface using Service Tool, if required
5
Connecting at least one registration unit to the device
6
Putting the device into operation by means of the setup medium via a registra-
tion unit
Before putting the device into operation, at least the door to be connected must be
planned in the partner application. The device is configured by assigning its installa-
tion site and the additional hardware components in this software.
For information on the planning of the system, see online help of the parter applica-
tion.
After the system has been planned in the partner application, a setup medium for
this system - also in the partner application - must be registered. This setup medium
is then used for commissioning the individual components used for the system , i.e.
for connecting them to the Internet platform.
A setup medium is a card with a code which must be activated in the partner appli-
cation for the corresponding system (add setup medium).
For information on the registration of a setup medium in the partner application, re-
fer to the online help of the partner application.
04045524 - 08/2016
Technical Manual
Kaba access manager 92 32