For 115V~/230V~: Use only SE30-77 AC Adapter. Für 115V~/230V~: verwenden Sie nur das X-Rite Netzteil P/N SE30-77. Para 115V~/230~: Use solamente el adaptador C.A. de X-Rite, pieza SE30-77. Pour 115V~/230~: Utiliser seulement l’adaptateur AC de X-Rite P/N SE30-77. Per 115V~/230~: Usare solamente il adattatore C.A. al X-Rite, pezzo SE30-77.
Directive(s) Conformance: EMC 89/336/EEC LVD 73/23/EEC WEEE As of August 13, 2005, X-Rite products meet the European Union – Waste Electrical and Electronic Equipment (WEEE) directive. Please refer to www.xrite.com for more information on X-Rite’s compliance with the WEEE directive.
Your instrument was packaged in a specially designed carton to assure against damage. If shipment is necessary, the instrument should be packaged in the original carton. If the original carton is not available, contact X-Rite to have a replacement shipped to you.
X-RiteColor AutoScan Spectrophotometer INSTRUMENT INTERFACE The instrument must be interfaced directly with one of the computer’s Serial or USB ports. For attachment to a Mac Mini- DIN 8 Serial Port, you need to use the optional adapter (P/N SE108-DB9PA-01). 1. Quit all programs and shut down the computer before installing interface cabling. 2.
Overview and Setup INSTRUMENT LED INDICATOR The LED indicates a variety of instrument operation conditions, such as calibration mode, and operation. Below is a complete list of all conditions reported by the LED. Operation Mode (Green Light) • Solid Green Light—self test passed and instrument is ready for use with defined strip. •...
Calibration and Measurement FREQUENCY OF CALIBRATION Typically, the host computer prompts for an instrument calibration when required. The frequency at which this occurs depends on the application. If desired, a reflection calibration can be invoked manually by pressing the Instrument button—refer below for procedure.
MEASUREMENT NOTE: The strip must have a 1.5” (38.10mm) leader before the leading edge of the first step (contact X-Rite Applications Support if additional information is required). Inspect the strip for spots or defects on the step. Defects may cause inaccurate measurements.
X-Rite will repair any instrument past warranty. The customer shall pay shipping and repair cost to the factory or authorized service center, and the instrument shall be submitted in the original carton, as a complete unaltered unit.
The calibration reference strip can be cleaned with a lint free cloth whenever required. Make sure to return reference strip to its protective case when finished. If required, a new reference strip can be ordered from X-Rite, Part Number DTP41-100-KIT. Always handle reference strip by the edges.
Press and hold the instrument button and plug-in power. Release button after LED starts to flash red (approx. 3 seconds). If you are still having a problem after performing a reset, contact X-Rite Customer Service toll-free by phone at: 1-888-826-3059; or by fax at: 1-888-826-3061.