General Characteristics - Cembre CPE-1 Operation And Maintenance Manual

Electro-hydraulic pump
Hide thumbs Also See for CPE-1:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
– When electrical equipment is used, basic safety precautions must be followed to reduce fi re
danger, electric shock and personal injury.
– Ensure the ON-OFF switch is in "0" position (off ) before connecting the pump to the mains supply.
– The operator should concentrate on the work being performed and be careful to maintained a
balanced working position.
– Hydraulic pumps manufactured by Cembre S.p.A. are developed for use with crimping or
cutting heads. According to this specifi c use, they do not need and are not equipped with
an oil non-return safety system.
For this reason, use in applications diff erent from those intended (for example with hydraulic
jacks, lifting systems or similar) can be dangerous for the operator.
Cembre S.p.A. does not accept any liability arising from the use of its hydraulics pumps
for applications different from those listed in its catalogues or other documentation.

1. GENERAL CHARACTERISTICS

PUMP TYPE:
Max. operating pressure
Oil supply
Single-phase electric motor:
supply voltage
current
Power
Control circuits
Oil reservoir capacity
Weight
Dimensions
Ingress protection:
Recommended oil:
Remote hand controller:
Remote pedal controller:
Safety: The pump is fi tted with a maximum pressure valve and pressure switch; MPC1 gauge (see page 38) is
available as an optional accessory to check the correct setting of the pressure switch.
Acoustic Noise (Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u)
– The weighted continuous acoustic pressure level equivalent A
at the work place L
pA
– The maximum value of the weighted acoustic displacement pressure C
at the work place L
pCPeak
– The acoustic power level emitted by the machine L
is equal to ..........................................................................................................................................................................88 dB (A)
5
ELECTRO-HYDRAULIC PUMP
CPE-1
bar (psi):
litres/min (gpm):
230 ~ / 50-60
Volt/Hz:
4,8 (50 Hz)
4,6 (60 Hz)
Ampere:
Watt (HP):
Volt:
litres (gal.US):
kg (lbs):
mm (inches):
is equal to ...............................................................................................................................73 dB (A)
is ..................................................................................................................................... < 130 dB (C)
WARNING!
CPE-1-110
700 (10,000)
110-115 ~ / 50-60
9,6 (50 Hz)
9,2 (60 Hz)
372 x 223 x 482 (14.6 x 8.8 x 19)
ENI ARNICA ISO 22 or ESSO INVAROL EP 22 or equivalent
×
WA
CPE-1-MG
CPE-1-110-MG
500 (7,250)
0,8 (0.21)
230 ~ / 50-60 [CPE-1-MG]
110-115 ~ / 50-60 [CPE-1-110-MG]
9,6 [CPE-1-MG]
9,2 [CPE-1-110-MG]
1050 (1.4)
24 DC
2,0 (0.52)
21 (46)
IP 55
×
ENGLISH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpe-1-110Cpe-1-mgCpe-1-110-mg

Table of Contents