Writing And Rewriting The Pld Internal Data - Sony WLL-CA50 Maintenance Manual

Wireless camera transmitter
Hide thumbs Also See for WLL-CA50:
Table of Contents

Advertisement

1-12. Writing and Rewriting the PLD
Internal Data
This unit uses the PLD (Programmable Logic Device) that
supports the e-Production (EPR) system to write and
rewrite the internal data.
If the part listed below needs to be replaced or to be
upgraded, contact your Sony Sales Office/Service Center.
n
The part number of PLD (or ROM for PLD) in which data
is not written yet, is shown in "Section 3. Spare Parts".
e-Production system has the advantages shown
below.
. To write/rewrite the PLD internal data:
1. The standard fixture (cable) can be used.
2. The standard software (PLD Download Tool) can be
used.
. The PLD internal data is controlled in the Sony Database
Server under the name Project file (E_xxx_xxx_xx_xx).
. The printed circuit board is equipped with the standard
connector (EPR connector) to write the PLD internal
data. The indication "EPR" is shown on the printed
circuit board.
Corresponding PLD
PLD
EPR connector
(Ref No./board name) (Ref No./board name)
IC200/DPR-231
CN14/ MB-998
*
IC502/DPR-231
* : IC502 is the ROM for IC200.
Equipment required
. PLD download fixture
(Sony part number: J-7120-140-A)
The cable connected PC to this unit.
. PC
A PC having parallel port.
A PC in which the PLD Download Tool software is
already installed.
For the applicable OS and the operating environment,
refer to "Download Tool Operating Instruction for
Device Programming".
WLL-CA50
Data write procedure
Data write procedure in the PLD (or ROM for PLD) is
outlined below.
For details of data write procedure, refer to "Download
Tool Operating Instruction for Device Programming"
which is available in the same site where the PLD Down-
load Tool software is available.
1. Prepare the Project file.
2. Turn off the power of this unit. Connect the PC
3. Turn on the power of this unit.
4. Program the PLD (or ROM for PLD) with the Down-
5. Upon completion of programming, check that error
Project file No.
E_000_000_95_xx
n
Download the Project file from the Sony Database
Server.
parallel port to the EPR connector of the target board
using the PLD download fixture (cable).
Start the Download Tool software and read the Project
file.
load Tool software.
message is not displayed. Turn off the power of this
unit and back on.
1-11 (E)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wll-ca50 ucWll-ca50 jWll-ca50 ce

Table of Contents