Electrical Alignment; Preparation; Equipment Required; Notes On Adjustments - Sony WLL-CA50 Maintenance Manual

Wireless camera transmitter
Hide thumbs Also See for WLL-CA50:
Table of Contents

Advertisement

2-1. Preparation

2-1-1. Equipment Required

Fixture
Extension board EX-819
(Sony Part No. : A-8327-481-A)
Measuring Equipment
. Frequency counter: Advantest R5362B or equivalent
. Oscilloscope:
Tektronix TDS3054B or equivalent
Peripheral Equipment
. AC adaptor:
AC-550/550CE or AC-DN2B, or
Battery pack: BP-L60A/L40A/M50/M100/IL75
n
The alignment can be performed without a camcorder.

2-1-2. Notes on Adjustments

. All measuring equipment shall be calibrated.
. To perform adjustment the DPR-231 board, extend using
the extension board.
Be sure to set the DC LINE switch to OFF before
disconnecting the board.
3
RV301
CN1
TP301
TP204
TP201
TP202
TP203
RV401
DPR-231 BOARD (A SIDE)
WLL-CA50
Section 2

Electrical Alignment

2
1
A
B
RV101
TP103
TP102
C
TP101

2-2. Free-run Adjustment

Preparations
1. Set the DC LINE switch of the unit to OFF, and extend
the DPR-231 board using the EX-819 board. (Refer to
the steps 1 to 3 of Section 1-13.)
n
If the comcorder is connected to the unit, set the power
switch of the comcorder to OFF, too.
2. Only set the DC LINE switch of the unit to ON, and
warm up the unit for about ten minutes.
3. Connect the TP101 on the DPR-231 board to the GND
E1 on the EX-819 board.
4. Connect each equipment as shown in the figure.
CH2
IN
Oscilloscope
Probe
Adjustment Procedure
Equipment:
Frequency counter
Test Point:
TP103/DPR-231 board
GND:
E2/EX-819 board
Adjustment Point: 1RV101/DPR-231 board
27.0 ± 0.1 MHz
Specifications:
Setting after Adjustment
Restore the DPR-231 board to the original position.
CH2
IN
OUT
Frequency
counter
2-1 (E)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wll-ca50 ucWll-ca50 jWll-ca50 ce

Table of Contents