Download Print this page
Chauvin Arnoux AEMC MN352 User Manual

Chauvin Arnoux AEMC MN352 User Manual

Ac current probe

Advertisement

Quick Links

AC Current Probe
Models MN352 and MN353
User Manual
DESCRIPTION
The MN352/353 (Catalog #2116.26 and #2116.27) are the latest in compact AC current probes.
Designed to meet the most stringent demands in industry and electrical contracting, they also meet the
latest safety and performance standards. The probes have a measurement range up to 240 Arms which
make them perfect tools for measurements with DMMs, recorders, power and harmonic meters. The
Models MN352/MN353 are compatible with any AC voltmeter, multimeter, or other voltage
measurement instrument that is capable of displaying 10mV of output per amp of measured current, an
accuracy of 0.75% or better and an input impedance of  1 M.
WARNING
The safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument. Read the instruction completely.
• Use caution on any circuit: potentially high voltages and currents may be present and may pose
a shock hazard.
• Do not use the probe if damaged. Always connect the current probe to the measuring device
before it is connected around the conductor
• Do not use on non-insulated conductor with a potential to ground greater than 600V CAT III
pollution 2. Use extreme caution when clamping around bare conductors or bus bars.
• Before each use, inspect the probe; look for cracks in housing or output cable insulation.
• Do not use clamp in wet environment or in locations that hazardous gases exist.
• Do not use the probe anywhere beyond the tactile barrier.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation. Use
only factory specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before
using the instrument.
This is a type A current sensor. This symbol signifies that application around and removal from
HAZARDOUS LIVE conductors is permitted.
DEFINITION OF MEASUREMENT CATEGORIES
CAT IV: For measurements performed at the primary electrical supply (<1000V) such as on primary
overcurrent protection devices, ripple control units, or meters.
CAT III: For measurements performed in the building installation at the distribution level such as on
hardwired equipment in fixed installation and circuit breakers.
CAT II: For measurements performed on circuits directly connected to the electrical distribution system.
Examples are measurements on household appliances or portable tools.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify
your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately
with the carrier and notify your distributor at once, giving a detailed description of any damage.

Advertisement

loading

Summary of Contents for Chauvin Arnoux AEMC MN352

  • Page 1 AC Current Probe Models MN352 and MN353 User Manual DESCRIPTION The MN352/353 (Catalog #2116.26 and #2116.27) are the latest in compact AC current probes. Designed to meet the most stringent demands in industry and electrical contracting, they also meet the latest safety and performance standards.
  • Page 2 2.56" (65 mm) .73" .83" (21 mm) (18.5 mm) Tactical Barrier (keep hands below this barrier) Black 2.00" (51 mm) 1.18" (30 mm) Phase Shift: ELECTRICAL SPECIFICATIONS 0.1 to 1A: Not Specified  3° 1 to 20A:  2° Nominal Range: 150A 20 to 80A: ...
  • Page 3 Crest Factor: Dimensions: 3 @ 150A peak max with an error 5.47 x 2.00 x 1.18" (139 x 51 x 30mm) (due to CF) of 3% Weight: Overload: 240A for 10 min ON, 30 min OFF 180 g (6.5 oz) Polycarbonate Material: Working Voltage: 600Vrms Jaws: Polycarbonate with 10% fiberglass charge,...
  • Page 4 Please write the CSA# on the outside of the shipping container. ® ® Chauvin Arnoux , Inc. d.b.a. AEMC Instruments 15 Faraday Drive  Dover, NH 03820 USA (800) 945-2362 (Ext.

This manual is also suitable for:

Aemc mn353Aemc 2116.26Aemc 2116.27Mn352Mn353