7. Test of Video Fader (BKNE-1011)
n
When starting the self diagnostics mode, the video fader
lever is at the bottom position.
This test is confirmed the transition operation of video
fader on BKNE-1011.
The confirmation of the operation is use the "LEVER" and
"AUDIO LEVEL METER R" LEDs.
If moving the video fader lever from bottom to top, the
twenty-five LEDs from the bottom of the "AUDIO
LEVEL METER R" light in order according to the actua-
tion of the video fader lever.
If the test conclusion is OK (All of the twenty-five LEDs
light.), the "LEVER" LED lights.
8. Test of Audio Faders (BKNE-1011)
This test is confirmed the transition operation of the audio
fader on BKNE-1011.
The "1", 2", "3", "4", "M" and "AUDIO LEVEL METER
R" LEDs are used to confirm the operation.
This test starts in order from the audio fader of the "1".
If moving each audio fader knob from bottom to top, the
twenty-five LEDs from the bottom of the "AUDIO
LEVEL METER R" light in order according to the actua-
tion of the audio fader knob.
The test conclusion is OK (All of the twenty-five LEDs
light.), the "1", "2", "3", "4" or "M" LED of each audio
fader knob light.
DNE-1000
9. Test of Knobs (BKNE-1011)
This test is confirmed to operate the knob of BKNE-1011.
The "KNOB" and "AUDIO LEVEL METERs L and R"
LEDs are used to confirm. The test starts in order from the
knob of the "1".
If turning each knob clockwise, the twenty-five LEDs from
the bottom of the "AUDIO LEVEL METER R" light in
order according to the actuation of the knob. If turning it
counterclockwise, the twenty-five LEDs from the bottom
of the "AUDIO LEVEL METER L" light in order accord-
ing to it.
If the test conclusion is OK (When turning the knob
clockwise and counterclockwise, all of the twenty-five
LEDs light.), the "KNOB" LED lights.
If the conclusion of all test is OK, the "AUDIO LEVEL
METER L and R" LEDs light.

4-1-5. Ending the Self Diagnostics Mode

After turning OFF the power switch of DNE-1000, turn
ON the power switch of DNE-1000.