8. INSTALLATION
INDOOR UNIT
8.1 DRAINAGE PIPE
1. The tube can be taken out in the direction right, rear left
or right.
Dx
8.2 CONNECTION PIPES
1. Point the tube fitting to the corresponding bell.
2. Pre-tighten the nut by hand
3. Adjust the strength of the couple according to the following
1. 2.
hose coupling
nut
pipe
8.3 INSTALLING THE DRAIN PIPE
1. Connect the exhaust pipe with the outgoing pipe from the
indoor unit.
2. Secure the joint with a ribbon.
1.
tube
external
16
Sx
Right rear
3.
torque copy T
inner tube
2.
condensate
drain pipe
2. Once you have decided to bring out the right pipe or the
left and cut the corresponding hole on the body.
chart. Place the open-ended wrench on the coupling of the
tube and insert the nut. Tighten the nut with a wrench.
4. Wrap the inner pipe and the coupling connection with the
insulating tube and then wrap the whole with adhesive tape.
key
Ø hex nut
nut
Ø 9,52
pipe
Ø 12
Ø 16
Ø 19
- Wrap with insulating tube inside the exhaust pipe in order to
prevent condensation.
- The expansion plastics particles are not provided.
of tube
exhaust
condensate
outer tube
tape
48
INS
cut pipe
torsion strength [Nm]
Ø 6
15 - 20
30 - 40
45 - 55
60 - 65