4.2 Normal Lighting and Shut-down Procedures

Normal Lighting Procedures

1. Make sure the system is filled with water and water is circulating in the system. Turn on
electrical supply and open the gas supply valves to the boiler.
2. Turn the on/off switch to the "On" position. If an error is indicated, refer to the NURO Advanced
User's Guide to troubleshoot the problem and take necessary corrective action before
proceeding.
3. Set the desired high temperature limit and operating temperature. The NURO
now begin the automatic firing sequence.

Normal Shut Down Procedures

1. Allow the boiler to turn off on its own once
the temperature satisfies, or remove the call
for heat to the boiler.
2. Once the boiler completes a successful
"Post-Purge" and "Post-Pump", it will return
to "Standby".
3. Once in standby, turn the on/off switch to the
"Off" position.
4. Close all manual gas valves to right.
5. Turn off the electrical disconnect to the
boiler.

4.3 Emergency Shut-Off

In case of emergency, immediately shut off the
gas supply at the valve on the top of the boiler.
See the image to the right for the location of the
gas valve.
Revised: March 15, 2021
Released: March 15, 2021
Check daily to be sure that the
immediate area around the boiler or
water heater is free and clear of any
combustible materials, including
flammable vapors and liquids.
© Patterson-Kelley 2021
All Rights Reserved.
P-K SOLIS™
Gas Fired Boiler
Technical Service 1.877.728.5351
®
controller will
Natural Gas
2701000090 P-K SOLIS NURO Installation and
Owners Manual (Rev A).docx
Page 55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solis sl-2000Solis sl-2500Solis sl-3000Nuro

Table of Contents