5.6 Open Windows function
When the Open Windows function is enabled in the configuration menu the
emitter automatically stops heating when it detects a sudden drop in the
temperature (4 °C in 20 minutes). This is normally caused when a window or
door is opened to the outside without turning off the emitter.
When the Open Windows function has been activated, it will be shown on the display by a single
screen with an open window.
In order to enable the heating again, the user must touch the Mode key. The emitter will then
return to the previous mode of operation.
Note: In installations where this function is activated very frequently, it may be appropriate to keep
it disabled.
* This function is taken into account by Directive 2009/125/EC regulations and will give the
unit more efficiency during operation.
5.7 Adaptive start control function
When the Adaptive start control function is enabled in the Configuration menu, the emitter
automatically starts heating prior to the programmed time (a maximum of 2 hours before), to
ensure that the next "on" set point is reached efficiently.
The emitter analyses the next two hours, and if there is a set point higher
than the current room temperature within that period, and knowing the hea-
ting speed of the unit, the software calculates when it needs to start heating.
This calculation is made every 5 minutes.
This function only runs when the emitter is in Program mode. When Adaptive start is running,
a flashing clock icon is displayed in the bottom left corner of the screen. This function will only
operate on temperature rise, e.g., from anti-frost to eco/comfort, or from eco to comfort.
When Adaptive start is running the emitter progressively increases the set point temperature until
the next programmed set point is reached.
* This function is taken into account by Directive 2009/125/EC regulations and will give the
unit more efficiency during operation.
5.8 Keyboard lock
The user can lock the emitter keyboard by touching and
holding the p and q keys for 2 seconds; the keyboard
can be unlocked in the same way.
When the keyboard is locked or unlocked, the following
screens are displayed: