Polarizer-Out Removal - Panasonic PT-EZ770Z Service Manual

Hide thumbs Also See for PT-EZ770Z:
Table of Contents

Advertisement

SECTION 2 DISASSEMBLY PROCEDURES

3.3.1. Polarizer-out removal

1. R emove each 1 screw-C on the polarizer holder and pull the
polarizer-out upward carefully.
Polarizer-out(R)
Note on handling of inorganic polarizer
This projector provides high durable inorganic polarizer which have a rib shaped evaporated aluminum on the glass sur-
face. This surface is very delicate. If touching or wiping the surface, the polarizing function will be lost due to damage of the
aluminium rib construction on the surface. Extreme care should be taken to handle the polarizer.
l Inorganic polarizer handling
Never grasp the surface or edges of the polarizer with bare hand. If fat and oil on your hand adheres on the edges
of polarizer, the linear bolt may appear on the glass surface due to capillarity. Grasp the edges of the glass with
new gloves or with tweezers when handling it.
l Inorganic polarizer cleaning
When removing the dust on the surface, use a commercial (inert gas) air spray or air blower to remove them. Never
use organic solvents.
Indication of light in-coming side and out-
going side
The indication of "in-coming side" and "out-going side" of
the polarizers or LCD panels is shown in the figure. It in-
dicates the light in-coming and out-going from the lamp.
Screen side
Out-going side
In-coming side
C
Cleaning capability of polarizers
In-coming
side
Polarizer-in
Lamp side
DIS-18
C
Polarizer-out(G)
(Inorganic type)
Al evaporated side
(light out side)
C
Polarizer-out(B)
(Inorganic type)
Al evaporated side
(light out side)
Type
R
Organic
Polarizer-
G
Inorganic
out
B
Inorganic
R
Inorganic
G
Inorganic
B
Inorganic
C
XYN2+F8FJ
wipe cleaning
In-coming side
Out-going side
OK
OK
NG
OK
NG
OK
OK
NG
OK
NG
OK
NG