SECTION 1 SERVICE INFORMATION
6. 2. 4. Error cord of system log
Bit
Error code (hex)
0
00000000 00000001
1
00000000 00000002 Not used
2
00000000 00000004 Exhaust air temperature warning
3
00000000 00000008 Not used
4
00000000 00000010
5
00000000 00000020 Not used
6
00000000 00000040 Exhaust air temperature error
7
00000000 00000080 Not used
8
00000000 00000100
9
00000000 00000200 Not used
10
00000000 00000400 Not used
11
00000000 00000800 Not used
12
00000000 00001000
13
00000000 00002000 Not used
14
00000000 00004000 Not used
15
00000000 00008000 Not used
16
00000000 00010000
17
00000000 00020000 Not used
18
00000000 00040000 Not used
19
00000000 00080000 Not used
20
00000000 00100000
21
00000000 00200000 Not used
22
00000000 00400000 Not used
23
00000000 00800000 Not used
24
00000000 01000000
25
00000000 02000000 Not used
26
00000000 04000000 Not used
27
00000000 08000000 Not used
28
00000000 10000000
29
00000000 20000000 Lamp cover not installed securely
LOWER
30
00000000 40000000 Not used
31
00000000 80000000 Not used
32
0000000100000000
33
00000002 00000000 Not used
34
00000004 00000000 Exhaust air temperature sensor disconnected
35
00000008 00000000 Air filter clogged sensor disconnected
36
00000010 00000000
37
00000020 00000000 Battery replacement for the internal clock
38
00000040 00000000 Angle sensor error
39
00000080 00000000 Not used
40
00000100 00000000
41
00000200 00000000 Not used
42
00000400 00000000 FAN1(LCD R) error/warning
43
00000800 00000000 FAN2(LCD G) error/warning
44
00001000 00000000
45
00002000 00000000 FAN4(PBS) error/warning
46
00004000 00000000 FAN5(LAMP1) error/warning
47
00008000 00000000 FAN6(LAMP2) error/warning
48
00010000 00000000
49
00020000 00000000 FAN8(EXHST) error/warning
50
00040000 00000000 Not used
51
00080000 00000000 Not used
52
00100000 00000000
53
00200000 00000000 Not used
54
00400000 00000000 Not used
55
00800000 00000000 Not used
56
01000000 00000000
57
02000000 00000000 Not used
58
04000000 00000000 Not used
59
08000000 00000000 Not used
60
10000000 00000000
61
20000000 00000000 Not used
62
40000000 00000000 Not used
63
80000000 00000000 Not used
Factor
Intake air temperature warning
Intake air temperature error
Lamp runtime warning
Lamp runtime has elapsed
Lamp failure
Lamp ignition error
No lamp installed
Not used
Intake air temperature sensor disconnected
Air filter clogged warning
Air filter not installed
FAN3(LCD B) error/warning
FAN7(POWER) error/warning
Not used
Not used
Not used
INF-30
Description
Internal temperature rising warning/ Error
• The ventilation holds are blocked
• Environment temperature is high
• Air filter clogged
The lamp runtime reaches 2 800 hours
The lamp runtime reaches 3 000 hours
Lamp failure
Lamp ignition error
- There is a possibility that has restarted in hot state.
Lamp is not installed (can not read out the data from
lamp memory)
Wrong type lamp is installed
Lamp cover is not installed securely
Intake air temperature sensor disconnected
Exhaust air temperature sensor disconnected
Air filter clogged sensor disconnected
Air filter may accumulate dust
Remaining battery level is low
Angle sensor failure
Air filter not installed
Fan or fan drive circuit has failure.
Fan replacement time