Panasonic PT-EZ770Z Service Manual page 22

Hide thumbs Also See for PT-EZ770Z:
Table of Contents

Advertisement

SECTION 1 SERVICE INFORMATION
• The following items are added to the sub menu "STATUS ".
1) Page 2
- EMULATE
-VERSION
- DIGITAL LINK
VERSION
- FPGA VERSION
- BALLAST
VERSION
2) Page 3
- COOLING CONDITION Cooling condition of cooling fan control
- VERTICAL TILT
- HORIZONTAL TILT Horizontal angle
3) Page 5
- TEMP (C)
- VOLT
- P MODE
- INST
- FAN MODE
- CLOG
- AMT
- APL
- LCD R
- LCD G
- LCD B
- PBS
- LMP1
- LMP2
- POWER
- EXHST
4) Page 6
- LAMP HISTORY
Emulate version
D IGITAL LINK microprocessor software ver-
sion
FPGA version
B allast microprocessor software version
Vertical angle
I ntake air temperature / Optical module tem-
perature / Exhaust air temperature
Voltage of LAMP
L amp power mode (AUTO, NORMAL, ECO1,
ECO2)
I nstall condition (DESK: Floor mount, CEIL:
Ceiling mount, VERT U: Upper mount, VERT
D: Lower mount)
F AN control mode (LOW/MID1/MID2/MID3/
MID4/HIGH/WARNING/SD)
Clog Temperature
A ir pressure sensor value/Air pressure tem-
perature
APL
LCD fan (R) condition [Rotation speed]
LCD fan (G) condition [Rotation speed]
LCD fan (B) condition [Rotation speed]
PBS fan condition [Rotation speed]
Lamp1 fan status [Rotational speed]
Lamp2 fan status [Rotational speed]
Power fan status [Rotational speed]
Exhaust fan status [Rotational speed]
Lamp On/Off status history log