Pass through oven

Advertisement

Power Cord:
Six (6) foot, 3 wire grounded cord. If the supply cord is damaged, the manufacturer, or an authorized
service agent, must replace it in order to avoid a hazard and warranty. Please contact the factory by
calling the 800 # located on the unit.
Shipping Weights:
XWAV1422
115 lbs. (52.2 kg.)
If the carton appears damaged, or damage is discovered once the carton is opened, stop
immediately and contact the freight company to file a damage claim.
CAUTION: The Pass Through Oven is shipped assembled. The unit is shipped with
urethane supports between the top heaters and the conveyor assembly. Please remove
!
all urethane supports and packaging materials before operating the unit. Failure to
remove all packaging materials may lead to a fire and / or damage to the appliance.
1. Remove all external packaging that is protecting top portion of unit.
2. Remove unit from shipping container while in the upright position. The unit can be lifted out of the
carton by grasping under the conveyor on each side of the appliance. Please remove the plastic
bag.
3. Remove all internal packaging to the unit.
inside the tunnel oven between the top heaters and the conveyor.
conveyor trays. Remove tape from extrusion corners. Remove tape from deflecting curtains
located just above entrance and exit of conveyor.
4. Visually inspect all external and internal portions of unit for damage.
top white ceramic elements located inside the oven tunnel after removal of urethane
supports.
To inspect these white ceramic elements, use a small mirror held under each element to
detect cracks.
stress. Do not twist, pull, push, or otherwise subject the white ceramic elements to
stress.
5. Wipe down the exterior of the unit using a
cleaners as they will damage the stainless steel surface and high temperature plastic.
NOTE: DO NOT USE CLEANERS OF ANY KIND ON THE WHITE CERAMIC HEATERS.
6.
Remove four feet from box and install into threaded nuts located at the four corners underside of the
left and right housings; Also remove conveyor extension tray(s). Conveyor extensions should be
hung off end of conveyor frame. Model XWAV 1422EZ and XWAV 1829EZ will have two conveyor
extensions for loading and exit ends.
7. Place unit in operating location.
Note
:
Ambient Conditions -
ambient temperature is held constant (minimum 70°F). Please avoid areas such as near
exhaust fans and air conditioning ducts.
Warning
:
Operating environment
Ensure that operation location is at a reasonable distance from combustible walls and materials
otherwise combustion or discoloration could occur.
important in maintaining proper division of inlet and exhaust air flow - If removed it could result in
improper functioning of unit and
XWAV 1829
149 lbs. (67.6 kg.)
4. INSTALLATION INSTRUCTIONS
Important: The Ceramic elements are fragile and will break under
Make sure that the operating location is in an area where the
MAY
XWAV1422EZ
115 lbs. (52.2 kg.)
Important: Remove urethane supports located
damp
cloth with warm water. Do not use abrasive pads or
Stand-off/Air-divider located on rear panel is
cause personal injury and
4
XWAV1829EZ
149 lbs. (67.6 kg.)
Remove tape from
Important: Inspect the
WILL
void your warranty.
!

Advertisement

loading

This manual is also suitable for:

Xwav-1422ezXwav-1829Xwav-1829ez