Specifications

Monitor Impedance .................................................................................................... > 400 kΩ @ 1 kHz
Loop Resistance (maximum) ............................................................................................................5 kΩ
Current Draw ............................................................................................................................ < 10 mA
DC Resistance
Talk Mode ............................................................................................................................< 300 Ω
Idle ..................................................................................................... > 10 MΩ (30 µA @ 300 VDC)
Monitor ................................................................................................ > 10 MΩ (30 µA @ 300 VDC)
Temperature
Operating .............................................................................................–34 to 60 °C (–29 to 140 °F)
Storage ................................................................................................–50 to 75 °C (–58 to 167 °F)
Battery ......................................................................................9 V alkaline (NEDA 1604A or IEC 6LR61)

Operation

Note: The test set must have a good battery installed in order to operate.
See "Changing the Battery or Cord Set" in this manual.
TALK
Press once to go off-hook (connect). To release the line connection press monitor.
To conserve battery life, the test set will shut off 5 minutes after removal from the line.
MONITOR
Press once to monitor the line without disturbing data, signal, or voice communication.
Press repeatedly to alternate between Monitor mode and off. If the test set is off-hook (connected)
pressing monitor will release the line connection.
To conserve battery life, the test set will shut off after 20 minutes of monitoring or
5 minutes after removal from the line.
MUTE
Press and release to stop transmitting over the line or to eliminate sidetones.
Press again to talk.