5. Prior to Operation
The equipment is easily
assembled and connected.
If in doubt, contact your
specialist sup-plier or qualified
electrician.

5.1 Installation

The equipment must be placed
on a plane and level surface,
suitable of bearing the weight of
the equipment fully filled with water.
 The installation location should
be well vented and protected from
atmospheric exposure.
 When operated at garden
pondsand pools the equipment
must be set up safe against
flooding and pro-tected from falling
into the water. Any additional legal
requirements are to be observed.
5.2 Suction line connection
A
Note:
Possibly further accessories
may be required for connection
(see "Availa-ble Accessories").
A
Caution!
The suction line needs to
be installed in such manner
that
it
does
not
mechanical force or distor-
tion to the pump.
Caution!
A
When pumping contaminated
fluids install a suction strainer
to pro-tect pump from sand and
dirt.
A
Note:
A check valve is recommended
to prevent water backflow when the
pump is switched off.
 All screw fittings are to be sealed
with thread sealing tape; leakages
cause priming of air and reduce or
prevent the priming of water.
 The suction line should be of at least
1" (25 mm) inner diameter; it must
be resistent to buckling and vacuum
proof.
 Keep suction line as short as practi-
cal, since with increasing length the
pump capacity is reduced.
 The
suction
towards the pump to prevent air
locks.
 A sufficient water supply must be
ensured, the foot valve at the end of
the suction line must be submerged
in water at all times.
5.3

Discharge port

A
Note:
Possibly further accessories may
be required for connection (see "Availa-
ble Accessories").
A
Caution!
The discharge (or pressure)
line needs to be installed in such
manner that it does not exert mechan-
i cal force or distortion to the pump.
 All screw fittings should be sealed
with thread sealing tape to prevent
leakage.
 All parts of the pressure line must be
resistant to internal pressure.
 All parts of the pressure line must be
installed in a workmanlike manner.
A
Danger!
Improper installation and use
of parts not resistant to internal pres-
sure can cause the pressure line to
break during operation. Risk of per-
sonal injury by liquid spurting from
the line under high pressure!
5.4
Mains connection
B
Danger! Risk of electric shock!
Do not operate the equipment
in wet environment and only under
exert
the following conditions:
 Connect only to an earthed outlet
that is properly installed, earthed
and tested.
 Mains voltage and fuse protection
must correspond to those stated
in the "Technical Specications".
 When operated at pools, garden
ponds and similar locations, the
equipment must be protected by
a
residual
device (RCD, 30 mA) (DIN VDE
0100 -702, -738 or equivalent
applicable local regulations).
We recommend the use of RCD's
as a general precaution for per-
sonal protection.
 When used outdoors all electri-
cal connections must be of the
splash-proof type; thez must not
be placed in water.
 Use only extension cables of suf-
ficient lead cross section (see
"Technical
Unroll cable reels fully.
EN
5.5
line
should
raise
A
or priming of air the pump needs to
be filled with water. Starting the pump
without water causes damage!
A
be filled, the pump is self-priming. How-
ever, depending on length and diameter
of the suction line it may take some time
until pressure has built up.
1.
2.
3.
4.
5.
6.
7.

6. Operation

Pump and suction line must be con-
nected and filled (see "Prior to Opera-
tion").
A
there is always sufficient pumping
medium (water) available.
x

Commissioning

A
current
operated
ON/OFF switch is switched ON.
1.
2.
3.
4.
A
not let pump run for more then
Specifications").
10 minutes, otherwise there could be
damage by the water overheating in
the pump.
Filling the pump and
priming
Caution!
After installation, loss of water
Note:
The suction line does not need to
Remove the water filler plug, com-
plete with gasket.
Slowly pour in clear water, until the
pump is filled.
To reduce the time needed for prim-
ing you can also fill the suction line.
Replace the water filler plug, com-
plete with gasket.
Open pressure line (open tap or
spray nozzle) for any air to escape
during priming.
Start equipment (see "Operation").
Switch equipment OFF when water
runs out steadily.
Caution!
Pump must not run dry. Ensure
If the motor does not start, no pres-
sure is built up or similar effects are
evident, switch the equipment OFF
– and try to remove the fault (see
"Trouble Shooting").
Note:
This pumps runs as long as the
Plug power cable in.
Switch pump on with the ON/OFF
switch.
Open pressure line (open tap or
spray nozzle).
Check to see that the water comes
out!
Caution!
With a closed pressure line do
5 4