STIEBEL ELTRON HDB-E 12 Si Operation And Installation page 23

Electronically controlled instantaneous water heater
Hide thumbs Also See for HDB-E 12 Si:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
INSTALLATION
Installation
f Press the two locking hooks and remove the lower part of
the back panel towards the front.
f Mark out the holes to be drilled; see chapter "Specification /
Dimensions and connections".
f Drill the holes and secure the mounting bracket with
2 screws and 2 rawl plugs (screws and rawl plugs are not
part of the standard delivery).
Note
If you are installing the appliance with flexible water con-
nections. secure the back panel with a screw.
f Fit the mounting bracket.
• 
f Prepare the power cable.
Making the water connection
Material damage
!
Carry out all water connection and installation work in
accordance with regulations.
f Seal and insert the twin nipples.
www.stiebel-eltron.com
160
1
2
1 DHW tee
2 Cross-piece
f Secure the tee and cross-piece, with a flat gasket each, to the
twin nipples.
Fitting the strainer
Material damage
!
The strainer must be fitted for the appliance to function.
f When replacing the appliance. check that the strain-
er is present.
f Fit the strainer provided in the cold water inlet of the
appliance.
Installing the DMB flow limiter
f Install the flow limiter provided in the cold water inlet of the
appliance.
HDB-E Si |
23

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents