Intended Use; Unpacking; Technical Specifications - Ikra GLSI 260 Operating Instructions Manual

Electric leaf blower vacuum
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19

Intended use

The leaf vac is exclusively used in the two following ways:
1. As a leaf vac for vacuuming up dry leaves.
2. As a blower it is used to collect together dry leaves or to remove them from inaccessible places (e.g. under vehicles).
In suction mode it also works as a shredder, where the volume of the leaves is reduced by a ratio of approx. 10:1
and takes up less space in the leaf collection bag and the collected material is simultaneously prepared for possible
composting.
Each type of use other than those given in these instructions for use can damage the machine and cause serious
risk to the user.
Please always observe the safety instructions in order to safeguard your guarantee claim and in the interests of prod-
uct safety. Due to the machine's design, we are unable to fully exclude all residual risks.

Unpacking

Due to modern mass production techniques, it is unlikely that your power tool is faulty or that a part is missing. If you
find anything wrong, do not operate the tool until the parts have been replaced or the fault has been rectified. Failure
to do so could result in serious personal injury.
Electric Leaf Blower/Vacuum

Technical Specifications

Rated voltage
Rated frequency
Rated power consumption
Rotation
Max. blowing speed
Max. air volume
Bag volume
Weight without cable
Protection class II
The A-rated sound pressure level of the device measured in accordance with EN ISO 22868 is:
Working-place-related emission value L
Vibration:
These values were measured in accordance with the following standards: EN 60335-1:2012; IEC 60335-2-100:2002
This device has a radio interference suppression according to:
EN 55014-1/A2:2011, EN 55014-2/A2:2008, EN 61000-3-2/A2:2009, EN 61000-3-3:2008
Please wear ear protectors!
Noise emission information in accordance with the German Product Safety Act (ProdSG) and the EC Machine
Directive: the noise pressure level at the place of work can exceed 80 dB(A). In such cases the operator will
require noise protection (e.g. wearing of ear protectors).
GLSI 260
V~
220-240
Hz
50
W
2600
rpm
15.000 - 18.000
km/h
270
3
m
/ min.
7,5
l
45
kg
4,7
:
76 dB(A)
pA
1,7 m/s²
GB-6
[K 3,0 dB(A)]