Applying settings

The infrared electronics provide seven preset programmes for selection. Programme 1 is set at the factory.
Programme
Temporary
shutoff*
Programme 1
Programme 2
Programme 3
Programme 4
Programme 5
Programme 6
Inactive
Programme 7
Inactive
* Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, water flow is not started for 3 minutes
even if an object is detected.
** Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is initiated
for a duration of 5 minutes after 24 hours (usage-independent) or for a duration of 1 or 5 or 10 minutes after 72 hours (usage-
dependent) after the fitting was last used.
Safety note:
Ensure free draining in the case of activated automatic flushing.
Selecting a programme
The programme is selected via the infrared sensor system.
1. Activate setting mode:
Disconnect the power supply to the electronics and reconnect
after 10 s, see page 3, Fig. [11]. Setting mode is active for 3
minutes.
2. Hold finger against the lower area of the sensor system, see
Fig. [12].
The indicator lamp (A) in the sensor system flashes quickly.
3. Remove finger from the sensor system once the indictor
lamp goes out. Programme selection mode is activated.
4. Place finger against the lower area of the sensor system
again.
The programmes are displayed by groups of flashing signals
via the indicator lamp. The groups are separated by a pause.
5. Programmes and display:
Display starts with the programme that is currently set. The
number of flashing signals corresponds to the individual
programmes:
1 = Programme 1
Pause
2 = Programme 2
Pause
...
7 = Programme 7
Pause
After the group with 7 flashing signals, the routine starts
from the beginning.
1 = Programme 1
...
On/off
Active
Off
Active
On
Active
On
Active
On
Active
On
Off
On
Automatic flushing**
Flush interval Flush duration
-
72 h
5 min
24 h
5 min
72 h
10 min
72 h
1 min
-
72 h
5 min
6. Selecting a programme:
The programme is selected by removing the finger from
the sensor system during the pause after the required
programme. The corresponding flashing signals are
displayed again after the finger is removed.
7. A new programme can be selected within the next 5 s if
required. Programme selection mode is automatically
terminated if the finger is removed from the sensor system
before 5 s have elapsed.
Starting cleaning mode
Cleaning mode is activated by holding the finger against the
lower area of the sensor system (indicator lamp lights up
continuously, then flashes). Remove the finger when the
flashing signals start.
Terminating cleaning mode
Cleaning mode can be prematurely terminated by once more
holding the finger against the lower area of the sensor system
(the indicator lamp changes from flashing signals to lighting
up continuously). The finger can be removed once the
indicator lamp goes out or cleaning mode ends automatically
after 3 minutes.
22
Usage-dependent/
independent
-
-
Usage-dependent
Usage-independent
Usage-dependent
Usage-dependent
-
-
Usage-dependent
Duration
of thermal
disinfection
3.5 min
3.5 min
11 min
3.5 min
3.5 min
3.5 min
3.5 min