A-4
A
A: D
PPENDIX
ESCRIPTION OF
Primary Rate Access
Unit (PAU) Alarms
Alarm
F2 (RAI)
Yellow
F3 (LOS)
Red
F3 (OOF)
Red
F4 (AIS)
Blue
F5
(E1 only)
LED
S
The Primary Rate Access Unit (PAU) has a seven-segment display and LEDs
to show PRI-ISDN status as shown in the table below.
Condition
Carrier LED
Remote Frame
Green
Alarm
Loss of Signal
Red
Out of Frame
Green
Unframe All
Amber
ones Signal
Continuous
Green
CRC errors
Alarm LED
Description
Amber
The remote end has lost framing or
signal and sends this alarm to the
Primary Rate Access Unit.
Red
The T1 or E1 signal has been lost. The
Primary Rate Access Unit declares a
red alarm and sends out a yellow
alarm to the remote end.
Red
The T1 or E1 training signal has been
lost and the framed payload can no
longer be received. The Primary Rate
Access Unit declares a red alarm and
sends out a yellow alarm to the
remote end.
Amber
The remote end is sending out an all
ones signal. This usually occurs when
the remote end cannot send out a
framed signal. The Primary Rate
Access Unit declares a blue alarm.
Red
Primary Rate Access Unit receives
excessive CRC errors.