Water supply requirements
complying with WHO
Water quality
drinking water standards
Water pH
5-9
particle size max. 0.5 mm
Water particle
• always install with
content
supplied strainer
Water
0.1 - 30 °C
temperature
Inlet pressure
0.02 - 0.4 MPa (0.2 - 4 bar)
range
Power supply requirements
The AQtap can be used in the entire range
from 110 V up to and including 240 V.
• grid power AC
connection:
Power supply
110-240 V, 50/60 Hz
• solar panel DC voltage:
15-45 V / 3 A
Max. power
45 W
consumption
2.1.6 Disposing of the product
The batteries must be removed, before the
product is disposed of. The waste batteries
should be disposed of through the national
collective schemes.
Use appropriate waste collection services.
If this is not possible, contact the nearest
Grundfos company or service workshop.