Page 2
The rating plate of the device is located on the enclosure base. SATEL aims to continually improve the quality of its products, which may result in changes in their technical specifications and software. Current information about the changes being introduced is available on our website.
Detects shocks and vibrations accompanying attempts to force open a door or window. Detects open door, window, etc. Water flood detector Detects flooding in spaces provided with plumbing systems. Flood probe is not included with the detector. The FPX-1 probe is offered by SATEL.
SATEL MXD-300 2 Description Radio transmissions Every 15 minutes, the detector sends information about its state (periodical transmission). Additional radio transmissions take place as a result of alarm. Alarms Described below are circumstances in which the detector reports alarm, depending on the detector type.
MXD-300 SATEL the detector operates like in the “Normal” mode (regardless of which operating mode was set using the jumper). The LED is flashing for about 2 seconds from inserting the battery, signaling the warm-up of the detector. The LED is also enabled in the test mode, in which it indicates: ...
SATEL MXD-300 3 Selecting detector type Detector type Configuration “OTS” pins – jumper on in “T” or “S” position (Fig. 8). Magnetic contact “SHOCK OFF” pins – jumper on (Fig. 7). “F” pins – jumper off (Fig. 4).
MXD-300 SATEL Fig. 5. Selecting the operating mode: jumper off – normal mode, jumper on – energy save mode. Fig. 6. Selecting the sensitivity of the roller shutter input: jumper off – registering 8 pulses in 120 seconds will trigger alarm, jumper on –...
Page 9
SATEL MXD-300 perform a test in order to establish the actual detection range of the detector. Mounting the detector on ferromagnetic surfaces or near to strong magnetic and electrical fields is not advisable, because it can result in malfunctioning of the detector.
Page 10
MXD-300 SATEL not received, select a different mounting location and repeat the test. Sometimes, it is sufficient to shift the detector ten or twenty centimeters. 8. Remove the front cover. 9. If detectors or flood probe are to be connected to the input terminals, make a hole in the enclosure base, run wires through the hole and secure them to the terminals.
Page 11
SATEL MXD-300 The shock detector range depends on the type of surface on which the detector is installed. The specified detection range (up to 3 m) should be considered an approximate value. The actual range should be determined experimentally after securing the detector to the surface.
MXD-300 SATEL 5 Specifications Operating frequency band................ 433.05 ÷ 434.79 MHz Radio communication range (in open area): PERFECTA .................... up to 600 m VERSA-MCU / MTX-300 / MICRA ............up to 500 m MRU-300 ....................up to 300 m Battery........................CR123A 3 V Battery life expectancy ..................
Page 13
SATEL MXD-300 Maximum current consumption ..................22 mA Complied with standards ..EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-2-6, EN 50131-5-3 Security grade according to EN50131-2-6 ..............Grade 2 Environmental class according to EN50130-5 ................. II Operating temperature range ................-10°C...+55°C Maximum humidity ......................
Need help?
Do you have a question about the micra MXD-300 and is the answer not in the manual?
Questions and answers