Command
Code
D3h
D4h
D5h
D6h
D7h
FBh
Note 1:
Status will retain the last occurrence. Latch defined as the status. Must be cleared
through the 03h (CLEAR_FAULTS) command. Please See the following Table.
Note 2:
READ_TEMPERATURE_1 should provide the PDB Inlet Ambient temperature.
Note 3:
Read Total Power command only at +12 V, 3V3, 5V total power.
Note 4:
Buzzer will alert when any PSU fault occurs. Write 0x20 command in PMBus will be
able to mute buzzer alarm. When PSU goes back to normal state, the register will be
set at 0x00.
Contents in 20h (VOUT_MODE) Command Code:
Mode
Linear
www.acrosser.com
Command Name
READ_3V3_IOUT
REDA_3V3_POUT
READ_5V_VOUT
READ_5V_IOUT
READ_5V_POUT
Buzzer_Mute (4)
Command
79h
7Ah
7Bh
7Dh
80h
B0h
Bits [7:5]
000b
Status Name
STATUS_WORD
STATUS_VOUT
STATUS_IOUT
STATUS_TEMPERATURE
STATUS_OF_3V3 And 5V
PSU_STATUS
Bits [4:0] (Parameter)
Five bit two's complement exponent for the mantissa delivered as
the data bytes for an output voltage related command.
ANR-C62xN1 Series
Data Format
Read Linear
Read Linear
Read VOUT Mode
Read Linear
Read Linear
R/W Byte
Status action
Automatic recovery
Number of
Data Bytes
2
2
2
2
2
1
Latch
Latch
Latch
Latch
Latch