Huawei SUN2000 M0 Series User Manual page 39

Table of Contents

Advertisement

SUN2000-(3KTL-10KTL)-M0
User Manual
No.
E
F
G
H
● Note a: WLAN-FE Smart Dongle: For details about the SDongleA-05
● Note b: The SUN2000-8KTL-M0 and SUN2000-10KTL-M0 inverters are not
Table 5-2 Cable description
No.
1
2
Issue 06 (2020-10-23)
Component
SmartLogger1
000A
Electricity
meter
Power grid
scheduling
device
a
AC switch
SDongleA-05 Quick Guide (WLAN-FE) ; 4G Smart Dongle: For
operation, see
details about the SDongleA-03 operation, see
(4G) . You can obtain the quick guide at
enterprise
by searching for the Smart Dongle model.
applicable to Australia.
Name
DC input power cable
(Optional) RS485
communications cable
(used to cascade
inverters or connect to
the RS485 signal port
on the SmartLogger)
Copyright © Huawei Technologies Co., Ltd.
Description
Select a proper model based on
requirements.
The recommended electricity
meter model is DTSU666-H.
Choose a device that meets
requirements of power grid
scheduling.
Recommended: a three-phase
AC circuit breaker with a rated
voltage greater than or equal
to 415 V AC and a rated
current of:
● 16 A (SUN2000-3KTL-M0,
SUN2000-4KTL-M0,
SUN2000-5KTL-M0,
SUN2000-6KTL-M0)
● 25 A (SUN2000-8KTL-M0,
SUN2000-10KTL-M0)
https://support.huawei.com/
Type
Standard PV cable in
the industry
Two-core outdoor
shielded twisted pair
cable
5 Electrical Connections
Source
Purchased from
Huawei
Purchased from
Huawei
Provided by local
power grid
companies
Prepared by the
customer
SDongleA-03 Quick Guide
Recommended
Specifications
● Conductor cross-
sectional area: 4–6
2
mm
● Cable outer
diameter: 4.5–7.8
mm
● Conductor cross-
sectional area: 0.2–
2
1 mm
● Cable outer
diameter: 4–11 mm