In general Congratulations on your new HWAM insert. We are pleased that you have chosen a HWAM insert and confident that it will give you much pleasure. To ensure optimum operation and safety, we recommend that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by the retailer.
Page 8
The chimney and flue duct must be of flue class T400 and be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing. The required distance to combustible material must be complied with in accordance with the brand label. Ask your HWAM retailer for further information.
Page 9
It is possible to connect several devices to the same chimney. However, it is important to first check the applicable rules. Chimney sweeping To prevent the risk of chimney fires, the chimney must be cleaned every year. The flue duct and the smoke chamber above the baffle plate must be cleaned together with the chimney.
The HWAM I 30/55 consists of a moveable, external brickwork casing, as well as an insert that is pushed into place and connected once the brickwork casing has been assembled. The HWAM I 30/55 can be connected in two ways: 1.
Page 11
(1) of the chimney, and should only be done when the insert is assembled. Connecting external supply of fresh air The HWAM I 30/55 can be connected to fresh air systems. The fresh air system can be purchased separately. 2. Restructuring of brickwork around insert During the reconstruction, the outer casing should be carefully levelled off at a suitable height.
– IrIng manual wood Your first heating session The lacquer will be fully hardened after the stove has been used, and the door and the ashpan should be opened very carefully as there will otherwise be a risk that the gaskets will stick to the lacquer. In addi- tion the lacquer may initially give off an unpleasant odour, so make sure that the room is well ventilated.
Page 13
Put two or three pieces of wood weighing up to 1 kg each into the insert. The HWAM ®...
Insufficient firing If the fireproof materials in the combustion chamber are blackened after a heating session, the insert is polluting, and the HWAM Autopilot™ is not functioning properly. The bar must therefore be pushed to ®...
leanIng External cleaning Cleaning of the insert should only be performed when it is not in use/cool. Daily maintenance is limited to a minimum. It is easiest to vacuum the outside of the insert with a tiny nozzle with soft brushes. Cleaning the glass (drawing G) If it becomes necessary to clean the inside of the glass pane, lift the door halfway up and pull out the two top guide latches (1) on each side of the door in order to loosen them from the screws (2).
Cleaning Before chimney sweeping can be performed, the air control lever must be set all the way to the left to prevent soot and ash from entering the HWAM Autopilot™. Drawing C: ® Remove the smoke shelf (1). Push the plate forward and lift it up a bit to the side. Tilt one side downward.
Page 17
be loosened or tightened as follows: Remove the liner from the building-in cassette. Make sure the door of the combustion chamber (3) is closed. Attach the tightening tool (4) supplied with the stove to the toothed wheel (5). To tighten the spring so that the door closes more slowly (or can remain fully open), turn the toothed wheel (5) clockwise slightly.
Stop using the stove and contact the retailer. At interruptions that you cannot yourself rectify, you should contact the retailer. eclaratIon oF erFormance The DoP can be downloaded from our website via the following link: www.hwam.com/dop/i30-55 Page 18 of 20 pages...
• Always dispose of items in a way that is as sustainable as possible and that is in line with the current environmental protection, reprocessing/recycling and disposal technology HWAM A/S • Nydamsvej 53 • DK-8362 Hørning Page 19 of 20 pages...
Need help?