Drain Water Tempering System - Jackson AJX Series Installation, Operation And Service Manual

Conveyor dishmachines
Hide thumbs Also See for AJX Series:
Table of Contents

Advertisement

PARTS
To Machine Drain
8
From the existing drain, attach the two additional Tees (Item 7) using the 1 1/2" Close Brass Nipples (Item 8). Tighten the
Reducers (Items 6 and 9) into the Tees as shown above. Attach the Modified Compression Fitting (Item 10) into the 1 1/2"
to 1/4" Reducer (Item 9). Position the bulb of the thermostat (Item 1) so that it rests approximately 1/4" from the bottom of
the Tee (Item 7). Tighten the Modified Compression Fitting (Item 10) as required.
Mount the Thermostat (Item 1) to the tub using the Thermostat Bracket (Item 2) and set it for 120–140 °F. Install the
Solenoid Valve (Item 3) to the second Tee (Item 7) and then attach to the incoming cold water line. Use thread tape as
required to prevent any leaks.
ITEM
QTY
1
1
2
1
3
1
4
2
5
1
6
1
7
2
8
2
9
1
10
1
07610-003-60-98-L

DRAIN WATER TEMPERING SYSTEM

Complete Drain Water Tempering System
1
9
7
8
7
DESCRIPTION
Thermostat
Thermostat Bracket
Solenoid Valve
Nipple, Close Brass, 1/2"
Valve, Check, 1/2"
Reducer, 1 1/2" to 1/2"
Tee, 1 1/2" x 1 1/2" x 1 1/2"
Nipple, Close Brass, 1 1/2"
Reducer, 1 1/2" to 1/4"
Modified Compression Fitting
05700-002-44-07
10
To Facility Drain
2
3
4
5
4
6
PART NUMBER
05930-003-13-65
05700-011-81-64
04810-100-12-18
04730-207-15-00
04820-002-55-77
04730-002-55-75
04730-011-69-93
04730-207-40-00
04730-002-55-76
05700-001-16-52
To Cold
Water Supply
59