1. Disconnect/turn off chemical feeder equipment.
2. Turn the machine on.
3. Add deliming solution according to chemical supplier's instructions.
4. Close door.
5. Flip AUTOMATIC/DELIME switch to DELIME.
6. Run the machine period of time recommended by chemical supplier.
7. Wait five minutes, then inspect inside of the machine. If the machine is not delimed,
run again.
8. Flip AUTOMATIC/DELIME switch to AUTOMATIC.
9. Run an empty rack through the machine twice.
10. Drain and re-fill the machine.
11. Reconnect/turn on chemical feeder equipment.
CAUTION! This equipment is not recommended for use with deionized water or other
aggressive fluids. Use of deionized water or other aggressive fluids will result in corrosion
and failure of materials and components. Use of deionized water or other aggressive fluids
will void the manufacturer's warranty.
OPERATING INSTRUCTIONS
L1
L2
L3
GRND
1