Motor Rotation; Ventilation; Thermostats - Jackson AJX Series Installation, Operation And Service Manual

Conveyor dishmachines
Hide thumbs Also See for AJX Series:
Table of Contents

Advertisement

INSTALLATION
MOTOR
ROTATION
i
!
CAUTION
CAUTION! On
3-Phase machines
only, correct pump

motor rotation

must be verified
before operation!

VENTILATION

THERMOSTATS

TABLE LIMIT
SWITCH OPTION
07610-003-60-98-L
On 3-Phase machines only, correct pump motor rotation must be verified before
the machine is operated. Failure to do so can result in damage to the machine and
components.
1. Follow the Power Up section.
2. Locate the wash pump motor and identify the arrow decal which shows the correct
motor rotation (if no decal is present, correct rotation is toward front of machine).
3. Flip AUTOMATIC/DELIME button to DELIME.
4. Flip ON/OFF button to ON.
5. Observe rotation of motor fan and quickly flip ON/OFF button to OFF.
6. If rotation is incorrect, disconnect electrical power and reverse the L1 and L2
connections at terminal block shown in the previous section.
The machine should be located with an adequate exhaust hood or ventilation system with
provisions for venting. This is essential to permit efficient removal of the condensation ex-
haust. Ensure the exhaust system is acceptable in accordance with applicable codes and
standards.
Any damage caused by steam and/or moisture due to improper ventilation
NOTICE
is NOT covered under the warranty.
Machine ventilation requirements:
Load End: 200 CFM
Unload End: 400 CFM
The exhaust system must be sized to handle this volume for the machine to operate
properly.
The thermostats on this machine have been set at the factory and should only be adjusted
by an authorized service agent.
There are two Table Limit Switch options available. Click on the instruction icons below for
install guides.
Striker Switch
INSTRUCTIONS
Whisker Switch
Motor Fan