Jackson AJX Series Installation, Operation And Service Manual page 28

Conveyor dishmachines
Hide thumbs Also See for AJX Series:
Table of Contents

Advertisement

SPECIFICATIONS
Local codes may require more stringent protection than what is displayed here and on the data plate. Always verify with your electrical
NOTICE
service contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual are
for reference and may change without notice.
On three-phase machines, imbalanced wild leg goes to L3. Also see the Motor Rotation section.
NOTICE
Information below is for machine components only. If using a third-party external booster, consult booster manufacturer for booster
NOTICE
information. For steam booster information, see Steam Line Connections section.
AJX-80/90CE
Volts
Phase
Freq
208
1
60 Hz
208
3
60 Hz
230
3
60 Hz
460
3
60 Hz
AJX-80/90CS
Volts
Phase
Freq
208
3
60 Hz
460
3
60 Hz
07610-003-60-98-L
ELECTRICAL REQUIREMENTS
Pre-wash
Wash
Motor
Motor
8.7 A
8.7 A
5.8 A
5.8 A
5.7 A
5.7 A
2.9 A
2.9 A
Pre-wash
Wash
Motor
Motor
3.3 A
5.8 A
2.9 A
2.9 A
i
Drive
Wash
Total Load
Motor
Heater
1.8 A
86.5 A
105.7 A
1.2 A
50.0 A
62.8 A
1.1 A
41.5 A
54.0 A
0.6 A
20.7 A
27.0 A
Drive
Wash
Total Load
Motor
Heater
1.2 A
N/A
10.3 A
0.6 A
N/A
MCA
107.9 A
64.2 A
55.4 A
27.7 A
MCA
11.8 A
6.3 A
7.0 A
MOP
115 A
70 A
60 A
30 A
MOP
15 A
15 A
20