12.3.9
Outdoor Unit Drain Water
Water will drip from the basepan hole area during
defrost function.
To avoid water dripping, do not stand or place
objects at this area.
12.3.10 Evaluation of the Performance
Operate the unit at cooling/heating operation
mode for fifteen minutes or more.
Measure the temperature of the intake and
discharge air.
Ensure the difference between the intake
temperature and the discharge is more than 8°C
during Cooling operation or more than 14°C
during Heating operation.
12.3.11 How to Replace Network Adapter
Remove the front grille (refer how to take out front grille) from the unit.
Remove the network adapter box by releasing the hook (Figure 1.0).
Remove the cover by unclipping it and pulling it out (Figure 1.1)
Remove the top casing by pressing the side of the network adapter box. (Figure 1.2)
After that, network adapter can be easily replaced (Figure 1.3).
Hook
Figure 1.0
Figure 1.1
Unclip & pull down
42
Discharge air
Press
Press
Figure 1.2
Hose
Figure 1.3