Model
Inner Diameter
Drain Hose
Length
Fin Material
Fin Type
Indoor Heat
Exchanger
Row × Stage × FPI
Size (W × H × L)
Fin Material
Fin Type
Outdoor Heat
Exchanger
Row × Stage × FPI
Size (W × H × L)
Material
Air Filter
Type
Power Supply
Power Supply Cord
Thermostat
Protection Device
Cooling
Indoor
Operation
Heating
Range
+8/15°C
HEAT
Cooling
Outdoor
Operation
Heating
Range
+8/15°C
HEAT
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.
6.
Maximum heating capacity shown are the values based on powerful operation.
7.
If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C DB and -8°C WB temperature with
rated voltage 230V shall be used.
8.
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode.
9.
SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating
season. Other fiche data indicates in an attached sheet.
Indoor
Outdoor
mm
mm
mm
mm
A
Maximum °C (°F)
Minimum °C (°F)
Maximum °C (°F)
Minimum °C (°F)
Maximum °C (°F)
Minimum °C (°F)
Maximum °C (°F)
Minimum °C (°F)
Maximum °C (°F)
Minimum °C (°F)
Maximum °C (°F)
Minimum °C (°F)
CS-HZ35UKE
CU-HZ35UKE
Aluminium (Pre Coat)
Slit Fin
2 × 17 × 21, Sub Eva × 2 : 1 × 4 × 21
636.5 × 357 × 25.4, Sub Eva × 2 : 636.5 × 73.4 × 12.7
Aluminium
Corrugate Fin
2 × 28 × 19
36.4 × 588 × 856.3:827.7
Polypropelene
One-touch
Indoor / Outdoor
Electronic Control
Electronic Control
Dry Bulb
32 (89.6)
16 (60.8)
30 (86.0)
16 (60.8)
15 (59.0)
8 (46.4)
43 (109.4)
16 (60.8)
24 (75.2)
-25 (-13.0)
-25 (-13.0)
15
16
650
Nil
Wet Bulb
23 (73.4)
11 (51.8)
26 (78.8)
11 (51.8)
18 (64.4)