12.2 Indoor Unit

12.2.1
How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from the vibration.
Measuring
Tape
HZ25***, HZ35***
The center of installation plate should be at more than 1 at right and left of the wall.
The distance from installation plate edge to ceiling should more than 2.
From installation plate center to unit's left side is 3.
From installation plate center to unit's right side is 4.
: For left side piping, piping connection for liquid should be about 5 from this line.
B
: For left side piping, piping connection for gas should be about 6 from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70 mm hole-core drill.
Line according to the left and right side of the installation plate. The meeting point of the extended line is
o
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
o
side.
12.2.2
To Drill a Hole in the Wall and
Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the bushing to the sleeve.
3
Cut the sleeve until it extrudes about 15 mm
from the wall.
When the wall is hollow, please be sure to use the
sleeve for tube assembly to prevent dangers
caused by mice biting the connection cable.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Wall
More than 1
(241.5 mm)
PIPE HOLE CENTER
DISTANCE
TO PIPE
HOLE
CENTER
(128 mm)
128 mm
Model
CAUTION
Wall
More
2 screw
than 2
(128 mm)
Installation
plate 1
Dimension
1
2
3
490 mm
90 mm
439 mm
Sleeve
for tube
assembly
ø70 mm
through hole
31
Wall
More than 1
DISTANCE TO
PIPE HOLE
CENTER 128 mm
(241.5 mm)
PIPE HOLE
CENTER
(128 mm)
4
5
432 mm
137 mm
85 mm
Wall
Indoor
Outdoor
15 mm
Putty or caulking compound
6
Approx. 5 - 7 mm
Bushing for tube
assemblys