Toshiba MMU-UP0091HP-E Service Manual page 101

Air conditioner (multi type)
Hide thumbs Also See for MMU-UP0091HP-E:
Table of Contents

Advertisement

DN
Item
33
T
e
m
p
e
a r
u t
e r
u
n
t i
s
e
e l
E
x
e t
n r
a
s l
a t
c i t
p
e r
s s
u
High-ceiling adjustment
5d
(Air flow selection)
Timer setting
60
(wired remote controller)
77
Dual set point
Alarm output setup of the
79
header unit
b3
Soft cooling
Occupancy sensor/
b5
Wireless Remote controller
Provided / None
Occupancy sensor
Enable / Invalid
b6
(Absence time judgment
time)
Occupancy sensor
b7
operation at absent time
4-way cassette type model
CF
name
Whether the power
d0
saving mode can be set
by the remote controller
Destination
E0
W
i
e r
e l
s s
e r
m
o
e t
E6
controller A-B selection
Swing mode
F0
Louver fixed position
F1
(Louver No.1)
Louver fixed position
F2
(Louver No.2)
Louver fixed position
F3
(Louver No.3)
Louver fixed position
F4
(Louver No.4)
Presence of Application
F6
control kit
(TCB-PCUC2E)
FC
Communication protocol *2
Priority operation mode
Fd
(FS unit)
FS unit address
FE
t c
0
0
0
0
° :
C
e r
R
f e
r e
o t
n
e
t x
p
a
g
. e
0000: Available
(can be performed)
0000: Unavailable
0000: Not including the state
of following unit
0000: Unavailable
0000: None
0002: Wireless remote controller provided
0000: Invalid
0002: 60min.
0005: 150min.
0000: Stand by
0000: Standard Model
0000: Invalid
0000: Japan
0004: Global
0
0
0
: 0
A
0000 : Out of sync swing
0002 : Dual swing
0000 : Release
0005 : Downward discharge position
0000 : Release
0005 : Downward discharge position
0000 : Release
0005 : Downward discharge position
0000 : Release
0005 : Downward discharge position
0000: None
0000 TCC-LINK
0000: Heating
0001: No.1 unit
to
0001: No.1 unit
to
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
Description
0
0
0
: 1
F °
0001: Unavailable
(cannot be performed)
0002: Available
0001: Including the state of
following unit
0001: Available
0001: Occupancy sensor
provided
0001: 30min.
0004: 120min.
0001: operation stop
0001: larger case model
0001: Valid
0003: China
0
0
0
: 1
B
0001 : 4-way sync swing
0003 : Cycle swing
0001 :
Horizontal discharge position
0001 :
Horizontal discharge position
0001 :
Horizontal discharge position
0001 :
Horizontal discharge position
0001: Exist
0003:TU2C-LINK
0001: Cooling
0064: No.64 unit
... TCC-LINK
0128: No.128 unit ... TU2C-LINK
- 101 -
At shipment
0
0
0
0
° :
C
Depending on model
type
0000: Available
0000: Unavailable
0000: Not including the
state of following
unit
0001: Available
0000: None
0002: Enable
(60 min.)
0000: Stand by
Depending on model
type
0001: Valid
0004: Global
0
0
0
: 0
A
0000: Not including
4-way
0001: 4-way (Compact)
0000: Not fixed
0000: Not fixed
0000: Not fixed
0000: Not fixed
0000: None
0000: TCC-LINK
0000: Heating
00Un/0099: Unfixed *1